Undercounter Installation - GE JTP30SM Dimensions And Installation Information

30" built-in single wall oven
Hide thumbs Also See for JTP30SM:

Advertisement

JTP30SM
GE
30" Built-In Single Wall Oven
®
Dimensions and Installation Information (in inches)
Optional Undercounter Installation with 36"
Gas Cooktop
3-1/4
3-1/2" MIN.
Free space
Conduit
(72" long)
1/2" Black
iron pipe
Pressure
regulator
Union
30" built-in
oven
Shut-off
valve
3/4" Support
4" To 4-1/2"
Right cabinet side
Side View
This installation is to achieve minimum gap between bottom of countertop and control panel.
Note: For this installation, the bottom trim will not be flush with a typical 4" toe kick.
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F
temperature rating.
Note: 36" ribbon cooktops are approved for use over GE 30" single wall ovens only. 30" ribbon
cooktops are approved for use over GE 30" and GE 27" single wall ovens. Refer to cooktop and
wall oven installation information packed with products for current dimensional data.
Installation Information: Before installing, consult installation instructions packed with product
for current dimensional data.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
2 (two) 90°elbows &
sufficient pipe to
connect in adjacent
cabinet
Junction box
for oven
Junction box in
adjacent cabinet
for cooktop
hook-up
22
Power cord
for cooktop
or
service,
Optional Undercounter Installation With 30" CleanDesign
or Sealed Burner Gas Cooktop
1-1/2" Typical countertop
Free space
1-1/2" MIN.
30-7/16
5-9/16"
Reference dim. for
MAX. support height
with typical 36" countertop
height
Add suitable filler
to match adjacent
cabinets when needed
to maintain toe kick
alignment

Undercounter Installation

Gas or electric cooktops may be installed over
this oven. See cooktop installation instructions
for cutout size. See label on top of oven for
approved cooktop models.
Junction box
25
location
240/208V
23-1/2" MIN.
Cutout depth
Top and/or side
fillers may be
necessary if unit
28-1/2'' MIN.
is positioned
28-5/8'' MAX.
between
Allow 11/16''
27-1/4'' MIN.
existing cabinets
overlap over side
27-5/16'' MAX.
edges of cutout
Cutout height
3/4'' Support
platform required
Match toe kick height
front and two sides
Specification Revised 10/07
30" Oven W/ Rad. Cktp.
Power cord
Junction box(s) for
oven & radiant
cooktop 22" from
floor
27-1/4" MIN.
27-5/16" MAX.
36" Typical
Countertop height
Cutout height
22
Reference
5-9/16
Side View
Gas (including the pressure regulator) and
Gas
electrical connections for gas cooktop must
connection
be located in an adjacent accessible location.
For a 30" gas cooktop, the connections are
5
more conveniently made to the right.
120 Volt
Outlet
1-1/2"
Countertop
22'' MIN. above
support platform
36'' MIN.
24
4'' To 4-1/2 '' Toe kick allowable
Listed by
Underwriters
Laboratories
320222