Honeywell Versa-Pro UDC3000 Specification

Honeywell Versa-Pro UDC3000 Specification

Versa-pro universal digital controller

Advertisement

UDC3000 Versa-Pro
Universal Digital Controller

Overview

The UDC3000 Universal Digital
Controller is Honeywell's general
purpose microprocessor-based,
stand alone digital controller. It
combines the highest degree of
functionality and operating sim-
plicity offered in a 1/4 DIN size.
The bright dual displays with multi-
language prompts make the
Operator Interface easy to read,
understand, and operate.
Programmed sequences of dis-
plays assure quick and accurate
entry of all configurable parame-
ters. Simple keystrokes let you
select input and range configura-
tion, set the operating parameters
that meet your process control
needs now, and change them later
to meet new ones.

Features

Dual Displays - Vacuum fluores-
cent alphanumeric displays and
indicators with dedicated PV
display.
Deviation Bargraph - "On Control"
indication or up to
10% deviation
display.
Easy Configuration - Multi-
language prompts, in programmed
sequence, provide guidance during
Configuration. Individual, reliable
tactile keys provide positive
operator feedback. There are no
internal jumpers to set.
Universal Isolated Input -
Input 1 accepts 10 thermocouple
types, RTDs, Radiamatic RHs, mA,
mV or voltage inputs through
keyboard configuration. It is isolated
from Input 2 and all other circuits.
(See Table 1.)
Thermocouple Failsafe -
Configurable upscale or downscale
burnout and failsafe output level.
Decimal Point Location -
Configurable for none, one, or two
places.
Industrial Automation and Control, 110 Virginia Drive, Fort Washington, PA 19034
L
ALM
1 2
DI
1 2
RSP
OUT
1 2
FUNCTION
SET UP
Figure 1 - UDC3000 Versa-Pro Controller
TM
Accutune II
- Provides a new,
truly plug and play tuning algorithm,
which will, at the touch of a button
or through a digital input, accurately
identify and tune any process
including those with deadtime and
integrating processes. This speeds-
up and simplifies startup plus allows
retuning at any setpoint. Also
included is the original Accutune SP
Adaptive tuning that can
automatically retune whenever a SP
step change is implemented.
Fuzzy Logic - This new feature
uses fuzzy logic to suppress
process variable overshoot due to
SP changes or externally induced
process disturbance. It operates
independently from Accutune
tuning. It does not change the PID
constants, but temporarily modifies
the internal controller response to
suppress overshoot. This allows
more aggressive tuning to co-exist
with smooth PV response. It can be
enabled or disabled depending on
the application or the control
criteria.
Printed in U.S.A.
Copyright 1997 Honeywell Inc.
L

Specification

F C
MAN
3000
%
SP 3000
LOWER
MANUAL
SETPOINT
DISPLAY
AUTO
SELECT
RUN
HOLD
Manual/Automatic Modes -
Bumpless, balanceless transfer
between control modes.
Two Local Setpoints - Can be
configured to provide two local
setpoints, keyboard or optional
remote switch selectable.
Universal Switching Power -
Operates on any line voltage from
90 to 264 Vac 50/60 Hz without
jumpers. 24V ac/dc instrument
power available as an option.
Limit Control - provides a latching
relay which is activated whenever
the PV goes above or below a
preset setpoint value. An alarm
indicator will light when the output is
activated. Reset is through a key on
the front of the controller or an
external switch.
Setpoint Rate - Lets you define a
ramp rate to be applied to any local
setpoint change. A separate
upscale or downscale rate is
configurable. A single setpoint ramp
is also available as an alternative.
51-52-03-07
2/97
Page 1 of 12
22069

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Versa-Pro UDC3000

  • Page 1 22069 needs now, and change them later to meet new ones. Figure 1 - UDC3000 Versa-Pro Controller Features Dual Displays - Vacuum fluores- Accutune II - Provides a new, Manual/Automatic Modes -...
  • Page 2 Control - You can use a single and 89/336/EEC, the EMC Directive signal, PV signal via digital inputs, UDC3000 to act as both an or motor slidewire input. (Table 1) Auto/Manual Station PLUS a back- Moisture Resistant Front Panel -...
  • Page 3 Current Output Model Output Algorithms German, Spanish and Italian. with 2 Alarms (DC300K-E) to be The UDC3000 is available with one also configured for time simplex, Control Modes or more of the following output time duplex, or three position step...
  • Page 4 51-52-03-07 Page 4 Upper Display - Six Characters • Normal Operation - four digits dedicated to display the process variable • Configuration Mode - displays parameter value or selection Lower Display - eight characters • Normal Operation - displays operating parameters and values •...
  • Page 5: Specifications

    51-52-03-07 Page 5 Specifications Design CE Conformity (Europe) This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other “CE Mark”...
  • Page 6 51-52-03-07 Page 6 Specifications (continued) Design (continued) Controller Output Types Current Output (Isolated) Range can be set anywhere between 0 to 21 mA, and as direct or reverse action. Resolution: 11 bits for 0 to 21 mA Accuracy: 0.5% full scale Temperature Stability: 0.1% F.S.
  • Page 7 10A Max. for 4 ms (under operating conditions) Power Inrush Current CAUTION When applying power to more than one UDC3000, make sure that sufficient power is supplied. Otherwise, the controllers may not start up normally due to voltage drop from the inrush current.
  • Page 8 51-52-03-07 Page 8 Specifications (continued) Environmental and Operating Conditions Parameter Reference Rated Operative Limits Transportation and storage Ambient ˚C ˚ ˚ ˚ 15 to 55 0 to 55 -40 to 66 Temperature ˚ ˚ ˚ ˚ 58 to 131 32 to 131 -40 to 151 Relative Humidity 10 to 55*...
  • Page 9 51-52-03-07 Page 9 General Reference Data Data AC Power : is electrically isolated from all other inputs and outputs to withstand a HIPOT potential of Isolation (Functional) 1900Vdc for 2 seconds per Annex K of EN61010-1. Analog Inputs and Outputs: are isolated from each other and all other circuits at 850Vdc for 2 seconds. Digital Input and Digital Output: are isolated from all other circuits at 850Vdc for 2 seconds.
  • Page 10 MANUAL SETPOINT FUNCTION DISPLAY SELECT AUTO SET UP HOLD Max Panel 2.4 with optional .945 Thickness .093 Max (2) rear cover .394 90.7 3.57 147.3 21.6 .850 5.82 22073 Figure 5 - UDC3000 Versa-Pro Controller dimensions - not to scale...
  • Page 11 51-52-03-07 Page 11 Wiring Diagram UDC 3000 EXTERNAL WIRING DI 1 CTL 1 DI 2 L1/H Instrument Power 4-20 MA L2/N SHIELD CTL 2 RX+/TX+ ALM 2 IN 2 RX-/TX- TX+ or AUX+ IN 1 ALM 1 TX- or AUX- 22840 NOTE: The product manual should be consulted for specific details and precautions regarding wiring.
  • Page 12: Ordering Information

    In Japan: Yamatake-Honeywell Co. Ltd., Nagai Int’l Bldg., 2 - 12 - 19 Shibuya-Ku, Tokyo 150 Japan, 81-3-3486-2051 In Asia: Honeywell Asia Pacific Inc., Room 3213-3225, Sun Hung kai Centre, No. 30 Harbor Road, Wanchai, Hong Kong, (852) 829-8298 In the Mediterranean: Africa and Middle East Region, Honeywell SpA, Via Vittor Pisani 13, 20124 Milano, Italy (39-2) 67731 Honeywell Pacific Division: Honeywell Pty Ltd., 5 Thomas Holt Drive, North Ryde Sydney, NSW Australia 2113, (61-2) 353 7000...