Summary of Contents for White Rodgers ComfortPlus HSP2000
Page 1
READ AND SAVE THESE INSTRUCTIONS Installation Instructions* for High-Capacity Steam Humidifiers (Models HSP2000 and HSP2600) Also includes: Programmable Flushing Timer Installation Instructions Operating and Maintenance Instructions CONTRACTOR: Read these instructions before install- ing or servicing humidifier HOMEOWNER: Save this manual for future reference.
Table of Contents For the Contractor: How To Install a White-Rodgers Page ComfortPlus Steam Humidifier CONTRACTOR: How To Install a White-Rodgers ComfortPlus Steam Humidifier .... NOTES: This humidifier must be installed by a qualified professional contractor. Failure to comply with this requirement may nullify the •...
Tools and Materials Needed CAUTION: For all installation configurations, the mounting area must be strong enough to support the humidifier’s weight when Safety glasses it is full of water (approximately 18 lbs.), and to hold the humidifier in Tin snips or aviation snips a level position for safe, reliable operation.
Page 4
Option C requires duct reinforcement Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the Water Level”, pages 8 & 9.) to hold the humidifier securely in place. DANGER: Wear safety glasses when Slide the flanges of the humidifier reservoir into the mounting bracket until the reservoir’s front flange comes in contact with the edge of the duct.
Plumbing and Setting the Water Level CAUTION: To prevent valve seat damage, never adjust the humidi- fier’s water level without supporting the float arm. Make adjustments NOTE: Use copper tubing only to plumb the humidifier. in small increments. Select the nearest cold water pipe and install the saddle connector and •...
How To Install the Locate a suitable waste drain for disposal of flushed water. Programmable Automatic Flushing Timer CAUTION: Drain tubing must not kink or come in contact with sharp edges or hot surfaces. Tubing must run in a continual down- The Humidifier Automatic Flushing Timer hill slope to allow proper drainage and to prevent overflow.
Inside, on the circuit board, locate the red switch block which contains Unplug the humidifier and fan control; disconnect the humidistat wires two switches, numbered 1 and 2. from the external screw terminals. NOTE: The switches are pre-set in the 10-second mode, Turn off the water supply and disconnect the supply tubing at the float with the #1 switch in the ON position and the #2 switch in the valve.
Condensation on walls Turn humidistat off Turn water to humidifier off until condensation is evapo- rated Figure 10—Parts Diagram of Models HSP2000 and HSP2600 Heavy condensation Turn humidistat down enough on windows to eliminate condensation (this Parts for Models HSP2000 and HSP2600...
For the Homeowner: Parts for Models HSP2000 and HSP2600 (cont’d.) How Your Humidifier Works Item Part Name Part No. Cover 000-0641-150 Transformer 120 Volt Primary, 24 Volt Secondary 000-0814-1 Your White-Rodgers Comfort- Plus Steam Humidifier sup- Transformer 240 Volt Primary, 24 Volt Secondary...
It even saves money on winter heating bills. That’s because NOTE: Some HSP2000 and HSP2600 models are equipped with a White- properly humidified air feels warmer, allowing you to turn your thermostat Rodgers Programmable Automatic Flushing Timer (see below), which can down a few degrees.
Page 11
If you have questions about your White-Rodgers ComfortPlus Humidifier, or to learn which White-Rodgers IAQ products are right for your home, contact your local heating and air conditioning contractor: 8100 W. Florissant Ave. St. Louis, MO 63136-9022 Web: www.white-rodgers.com Part No. 000-0756-14 HBP 6/06...