Safety Guidelines ......................5 Roof Warning, Operation & Safety ................6 Safety Alert Decals ...................... 7 Hardware List For FFD-200-1 & FFD-200-3 ..............8 Super Spread Parts List ..................... 10 Super Spread Parts Assembly ................... 11 Super Spread Installation ................... 12 Single Phase-Dual Voltage Wiring Diagram ...............
WARRANTY THE GSI GROUP, INC. ("GSI") WARRANTS ALL PRODUCTS MANUFACTURED BY GSI TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR A PE- RIOD OF 12 MONTHS AFTER RETAIL SALE TO THE ORIGINAL END USER OF SUCH PRODUCTS. GSI'S...
SAFETY GUIDELINES This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this equipment of these safety guidlines.To help you recognize this information, we use the symbols that are defined below.
ROOF WARNING, OPERATION & SAFETY ROOF DAMAGE WARNING AND DISCLAIMER GSI DOES NOT WARRANT ANY ROOF DAMAGE CAUSED BY EXCESSIVE VACUUM OR INTERNAL PRESSURE FROM FANS OR OTHER AIR MOVING SYSTEMS. ADEQUATE VENTILATION AND/OR "MAKEUP AIR" DEVICES SHOULD BE PROVIDED FOR ALL POWERED AIR HANDLING SYS- TEMS.
SAFETY ALERT DECALS Grain Systems, Inc. recommends contacting your local power company, and having a representative survey your installation so the wiring is com- patible with their system, and ad- equate power is supplied to your unit. Safety decals should be read and understood by all people in the grain handling area.
HP motor. Two types of motors are offered with the super spread. One has a single phase motor (FFD-200-1) and the other model (FFD-200-3) has a three phase motor. Maximum grain capacity is 4,000 to 6,000 bushels per hour, de-...
Page 9
ASSEMBLY INSTRUCTIONS Note: Remove blade extention 6. Turn the three spreader diverters (SPD-2002) for 24' & smaller bins outward (Figure 2). The diverters on the blade assembly are turned inward for shipping purposes. Further adjustments may be re- quired after installation. 7.
PARTS LIST FFD-200-1 (1 PH MOTOR) & FFD-200-3 (3 PH MOTOR) ITEM # PART # QUANTITY DESCRIPTION 002-1105-2 1 HP 1-Phase C-Face Motor (special) 002-1088-0 1 HP 3-Phase C-Face Motor (special) 017-1534-1 Pinion Gear SPD-2154 MI Gear Box With 56C Adapter (069-1304-0) TFC-0054 3/4"...
PARTS ASSEMBLY WARNING! Automatic Reset Overload Protection NOTE: Tighten set screws against flat on motor shaft Special Gearbox Lubricant Locating holes must be aligned for proper operation Not required for smaller bins...
INSTALLATION The units are shipped with the mo- The 1 HP motor is protected with This may be done by interchanging tor wires disconnected. Carefully an internal automatic reset overload. any two of the three power wire con- connect motor wires for desired op- However, it is advisable to provide nections.
INSTALLATION ELECT. OIL CAPACITORS SINGLE PHASE-DUAL VOLTAGE WIRING DIAGRAM 110 VOLTS 230 VOLTS •For 110 volts 1, 3 and the extra wire on the capacitor •For 230 volts 1 goes to L1. go to L1. •2 and 3 and the extra wire on the capacitor go •4 goes to L2, and 2 and J tie together.
Page 14
INSTALLATION Mount unit level inside the bin 1. Adjust hanger extensions to fit roof opening and install the power spread unit. Carpenter's level 2. Use the 9/32" hole at the end of each hanger extension and bolt Grain spreader hanger extensions to hatch collar.
OPERATING INSTRUCTIONS Grain Spreader Tilt Single spreader diverter end up for desired grain spread. Figure 8: Adjustment of the tilt. The grain spreader blade assembly the blade up and down. This ther. Angled grain diverters will has four features for adjusting grain may vary according to bin diam- reduce the throwing distance.
OPERATING INSTRUCTIONS ADJUSTMENT FOR BIN FILL LARGE BIN SMALL BIN 36" DIA. AND GREATER 24" DIA. AND LESS REF # PART TYPE OPERATION/PROCEDURE OPERATION/PROCEDURE Spreader Blade Tilt Decrease (flatten)/loosen U- Increase/loosen U-bolts and bolts and pivot the blade to pivot the blade (single diverter horizontal.
OPERATING INSTRUCTIONS MAINTENANCE For normal operation, annually not be more than 1/4" below the vent of rotation. If power does not exist, relubricate both motor bearings with plug (Figure 10). It may be neces- check for blown fuse or flipped cir- approximately ten drops of 5W-30 sary to insert a wire through vent cuit breaker.
TROUBLESHOOTING GUIDE CORRECT SPREADING PATTERN Grain is slightly depressed in the center, grain flow is centered and the spreader is level. Trouble Probable Cause Large doughnut shaped ring Tilt blade downward, decrease bite. caused by grain hitting high on bin Remove blade extension.