Physical Specifications - Cisco Catalyst 4500 Series Datasheet

Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Physical Specifications

Table 6 lists physical specifications.
Table 6.
Specification
Dimensions (H x W x D)
Rack units (RU)
Chassis weight (with fan
tray)
Mounting
Power Supply Indicators and Interfaces
Output Fail LED (per unit): RED
Input OK LED(per input): Green
Fan OK LED(per input): Green
Tables 7 and 8 describe power supply specification.
Table 7.
Power Supply
Integrated PoE
Input current (rated)
Output current (data)
Output power redundant mode (data)
Output power combined mode (data)
Heat dissipation
Holdup time
Hot-swappable
Table 8.
Power Supply
Integrated PoE
Input current
(rated)
Output current
(data)
© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Physical Specifications of Cisco Catalyst 4500 Series Chassis
WS-C4503-E
12.25 x 17.31 x 12.50 in.
(31.12 x 43.97 x 31.70 cm)
7RU
32.25 lb (14.63 kg)
19- and 23-in. rack
compatible (19-in. rack and
cable guide hardware
included)
Cisco Catalyst 4500E Series Power Supply Specifications (Data Only)
1000W AC
No (data only)
12A at 100 VAC, 5A at 240 VAC
● 12V at 83.4A
● 3.3V at 12.2A
1000W + 40W
1667W
943 Btus per hour
20 ms
Yes
Cisco Catalyst 4500E Series Power Supply Specifications (Data and PoE)
1300W AC
2800W AC
Yes
Yes
(up to 800W)
(up to 1400W)
● 16A at 100
● 16A at 200
VAC
VAC
● 7A at 240
VAC
● 12V at
● 12V at
84.7A
113.3A
● 3.3V at
● 3.3V at
12.5A
12.5A
WS-C4506-E
WS-C4507R+E
17.38 x 17.31 x 12.50 in.
19.19 x 17.31 x 12.50 in.
(44.13 x 43.97 x 31.70 cm)
(48.74 x 43.97 x 31.70 cm)
10RU
11RU
40.50 lb (18.37 kg)
44.50 lb (20.19 kg)
19- and 23-in. rack
19- and 23-in. rack
compatible (19-in. rack and
compatible (19-in. rack and
cable guide hardware
cable guide hardware
included)
included)
1400W AC
No (data only)
16A at 100 VAC, 7A at 240 VAC
● 12V at 113.4A
● 3.3V at 12.2A
1360W + 40W
2473W
1048 Btus per hour
20 ms
Yes
4200W AC
6000 AC
Yes
Yes
(up to 3855W)
(up to 4800W)
● Two 12A at
● Two 12A at
100 VAC
100 VAC
Or
Or
● Two 12A at
● Two 16A at
200 VAC
200 VAC
● 12V at
● 12V at
115.3A
186.9A
● 3.3V at
● 3.3V at
12.5A
12.5A
WS-C4510R+E
24.35 x 17.31 x 12.50 in.
(61.84 x 43.97 x 31.70 cm)
14RU
54.50 lb (24.73 kg)
19- and 23-in. rack
compatible (19-in. rack and
cable guide hardware
included)
1400W DC Triple Input
No (data only)
Two -48 VDC at 15A;
One -48 VDC at 12.5A
● 12V at 1360W
● 3.3V at 40W
1400W + 40W
-
1048 Btus per hour
8 ms
Yes
9000 AC
1400W DC with Power Entry
Module (PEM)
Yes
Up to 7500W (minus the power
(up to 7500W)
consumed for data) when
connected directly to a DC power
plant or 2 external AC power
shelves
● Three 12A
● 31A at -60 VDC (data only)
at 100 VAC
● 180A at -48 VDC (PoE)
Or
● Three 16A
at 200 VAC
● 12V at
● 12V at 120A
163.3A
● 3.3V at 12.5A
● 3.3V at
12.5A
Page 6 of 11