Mitsubishi Electric MSZ-GA22VA Operating Instructions Manual

Mitsubishi Electric MSZ-GA22VA Operating Instructions Manual

Split-type air conditioners
Hide thumbs Also See for MSZ-GA22VA:

Advertisement

SPLIT-TYPE AIR CONDITIONERS
Back to Index

OPERATING INSTRUCTIONS

INDOOR UNIT
MSZ-GA22VA
MSZ-GA25VA
MSZ-GA35VA
OPERATING INSTRUCTIONS
To use this unit correctly and safely, be sure to read this operating instructions
before use.
Bedienungsanleitung
Um diese Einheit richtig und sicher zu verwenden, unbedingt diese Bedienungs-
anleitung vor der Inbetriebnahme durchlesen.
NOTICE D'UTILISATION
Pour avoir la certitude d'utiliser cet appareil correctement et en toute sécurité, veuillez
lire attentivement cette notice d'instructions avant de mettre l'appareil en fonction.
GEBRUIKSAANWIJZING
Om dit apparaat op de juiste manier en veilig te gebruiken, dient u eerst deze
gebruiksaanwijzing aandachtig door te lezen.
MANUAL DE INSTRUCCIONES
Para emplear correctamente este aparato y por razones de seguridad debe leer
este manual de instrucciones de manejo antes de su utilización.
LIBRETTO D'ISTRUZIONI
Per utilizzare correttamente quest'unità, leggere questo libretto d'istruzioni atten-
tamente e per intero.
√¢∏°π∂™ §∂π∆√Àƒ°π∞™
°È· Ó· ¯ÚËÛÈÌÔÔÈ‹ÛÂÙ ·˘Ù‹ ÙËÓ ÌÔÓ¿‰· ÛˆÛÙ¿ Î·È Ì ·ÛÊ¿ÏÂÈ·, ‚‚·Èˆı›ÙÂ
fiÙÈ ¤¯ÂÙ ‰È·‚¿ÛÂÈ ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ Ô‰ËÁÈÒÓ ÚÈÓ ·fi ÙËÓ ¯Ú‹ÛË.
INSTRUÇÕES DE OPERAÇÃO
Para utilizar esta unidade correctamente, certifique-se de que lê estas instruções
de operação antes da utilização.
BRUGSANVISNING
Læs denne brugsanvisning før brugen så korrekt og forsvarlig anvendelse af klima-
anlægget sikres.
BRUKSANVISNING
För att använda enheten på rätt och säkert sätt ska denna bruksanvisning läsas
innan enheten tas i bruk.
‹fiLETME TAL‹MATLARI
Bu birimi do¤ru ve güvenli olarak çal›flt›rmak için, kullanmadan önce bu iflletme
talimatlar›n› mutlaka okuyun.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования прибора следует
до начала его эксплуатации внимательно прочитать данное руководство.
For customers
English
Für Kunden
Deutsch
A l'attention des clients
Français
Voor de klant
Nederlands
Para los clientes
Español
Per gli utenti
Italiano
°È· ÙÔÓ ÂÏ¿ÙË
∂ÏÏËÓÈο
Para os clientes
Português
Til kunden
För kunder
Svenska
Sat›n al›c›lar için
Для пользователей
Русский
Dansk
Türkçe

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSZ-GA22VA

  • Page 1: Operating Instructions

    Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez lire attentivement cette notice d’instructions avant de mettre l’appareil en fonction. INDOOR UNIT GEBRUIKSAANWIJZING Voor de klant MSZ-GA22VA Nederlands • Om dit apparaat op de juiste manier en veilig te gebruiken, dient u eerst deze MSZ-GA25VA gebruiksaanwijzing aandachtig door te lezen.
  • Page 2: Table Of Contents

    CONTENTS • SAFETY PRECAUTIONS ................................ 2 This air conditioner is NOT intended for use by children or infirm persons without supervisions. NAME OF EACH PART ................................3 PREPARATION BEFORE OPERATION ..........................4 WARNING AUTO CHANGEOVER... AUTO MODE OPERATION ......................6 Do not use intermediate connection of the power supply cord or the extension cord and do not MANUAL OPERATION (COOL, DRY, HEAT) ..........................
  • Page 3: Name Of Each Part

    SAFETY PRECAUTIONS NAME OF EACH PART Indoor unit CAUTION Do not use the unit for special purposes. • Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects. Air inlet This may cause deterioration of quality, etc. Heat exchanger Front panel Do not put a stove, etc.
  • Page 4: Preparation Before Operation

    NAME OF EACH PART PREPARATION BEFORE OPERATION Remote controller Auto restart function These models are equipped with an auto restart function. If you do not want to use this function, Signal transmitting section please consult the service representative because the setting of the unit needs to be changed. Auto restart function is ...
  • Page 5: Emergency Operation

    PREPARATION BEFORE OPERATION Remote controller Handling of the remote controller When the remote controller cannot be used (emergency operation) • The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in- How to set the batteries and the current time When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation door unit.
  • Page 6: Auto Changeover

    AUTO CHANGEOVER... AUTO MODE OPERATION An automatic cooling and heating changeover operation system ensures easy control and year-round Description of “AUTO RESTART FUNCTION” air conditioning. Once the desired temperature is set, unit operation is switched automatically between cooling and • These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start heating according to the room temperature.
  • Page 7: Manual Operation (Cool, Dry, Heat)

    MANUAL OPERATION (COOL, DRY, HEAT) AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT AIR FLOW velocity and direction can be selected as required. To select the COOL, DRY or HEAT mode: To change the AIR FLOW velocity, press the button. ON/OFF Press the button.
  • Page 8 AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT Movement of the horizontal vane To change the horizontal direction of the air flow, move the vertical vane manually. COOL/DRY HEAT At the start of heating operation When air becomes Horizontal Very small warm… position air flow Horizontal position...
  • Page 9: Econo Cool Operation

    ECONO COOL OPERATION WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Use this operation when you want to be comfortable in COOL mode even with energy saved. Perform the following operations while the unit is operat- When it is not going to be used for a long When the air conditioner is to be used ing in the MANUAL COOL mode.
  • Page 10: Cleaning The Front Panel, Heat Exchanger And Fan

    CLEANING THE FRONT PANEL, HEAT EXCHANGER AND FAN CLEANING THE CATECHIN AIR FILTER Front panel Heat exchanger Cleaning the catechin air filter (about once every 2 weeks) Hold both ends of the front panel and lift the Remove the catechin air filter before clean- Remove the catechin air filter.
  • Page 11: Cleaning The Air Cleaning Filter (Option)

    CLEANING THE AIR CLEANING FILTER (OPTION) REPLACEMENT OF THE AIR CLEANING FILTER (OPTION) When the capacity is lowered because of dirt, etc., it is necessary to replace the air cleaning filter. Cleaning the air cleaning filter (about once every 3 months) Remove the catechin air filter (left one).
  • Page 12: Cleaning The Air Outlet And Fan Of The Indoor Unit

    CLEANING THE AIR OUTLET AND FAN OF THE INDOOR UNIT Clean the air outlet and fan of the indoor unit. (Make sure the fan has stopped.) Before cleaning Switch the indoor unit off with the remote controller and disconnect the power supply plug and/or turn off the breaker, otherwise you may get injured since the fan of the in- door unit rotates at high speed during op-...
  • Page 13: Before Contacting The Service Representative, Check The Following Again

    BEFORE CONTACTING THE SERVICE REPRE- WHEN YOU THINK THAT TROUBLE HAS OCCURRED SENTATIVE, CHECK THE FOLLOWING AGAIN Question Answer (not a malfunction) Question Answer (not a malfunction) The air conditioner cannot • This protects the air conditioner according to in- The air flow direction •...
  • Page 14: Installation, Relocation And Inspection

    NOTE: 3. GA22 has no specifications for single com- Set name — MSZ-GA25VA(H) MSZ-GA35VA(H) 1. Rating condition bination. This indoor model is only for Model Indoor MSZ-GA22VA MSZ-GA25VA MSZ-GA35VA — MUZ-GA25VA(H) MUZ-GA35VA(H) multi system air conditioner. Outdoor Cooling — Indoor: 27°C DB, 19°C WB...
  • Page 15 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on • Low Voltage Directive 73/23/ EEC the following EU regulations: • Electromagnetic Compatibility Directive 89/336/ EEC HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN SG79Y402H01...

This manual is also suitable for:

Msz-gb50vaMsz-ga25vaMsz-ga35vaMsz-ga25vaMsz-ga35va

Table of Contents