Adjustment of phase in VS genlock mode (VS)
The adjusting video signal of the camera and the criterial external synchronizing input signal
are connected to a 2-input oscilloscope and the phase is adjusted. Follow the procedure below
to adjust the phase.
"CAMERA SETUP" screen
**CAMERA SETUP** 1/2
CAMERA ID
ALC/ELC
SHUTTER
AGC
SENS UP
SYNC
WHITE BAL
MOTION DET
DNR
RESOLUTION
BW MODE
"SYNC" screen
H PHASE
RET TOP END
34
OFF
ALC
OFF
ON
OFF
INT
ATW1
OFF
HIGH
HIGH
**SYNC**
... | ...128
-
+
Step 1
Provide a VS signal to the external synchro-
nizing input connector on the rear side of the
camera.
→ The
"SYNC"
changes to "EXT (VS)".
Step 2
Move the cursor to "EXT (VS)" and press the
setting button.
→ The "SYNC" screen appears.
Step 3
Connect the video output signal and external
synchronizing input signal of the camera to a
2-input oscilloscope, and move the cursor to
"H PHASE".
Step 4
Adjust the oscilloscope to the horizontal rate,
and extend the horizontal synchronizing part
of the oscilloscope.
Move the cursor horizontally to adjust the
horizontal phase with use of the right or left
button.
Adjustable range: 0 to –2.0 µs
setting
automatically