GE  Profile PP989DN Dimensions And Installation Information

GE Profile PP989DN Dimensions And Installation Information

30" downdraft electric cooktop

Advertisement

Quick Links

PP989SN
GE Profile
30" Downdraft Electric Cooktop
Dimensions and Installation Information
Wall Installation: Wall installations
KW Rating
require 25" countertop depth. When
240V
9.1
cabinet is flush against the wall, the
fan housing can be rotated to the
208V
6.9
horizontal position for direct venting
through rear wall. Make a countertop cutout in the range
cabinet according to unit dimensions and installation type.
Duct hole is positioned in back of cabinet for through-the-
wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a
minimum 26" countertop depth is suggested. Blower should
be in vertical position. Island or peninsula cabinets may
require adjustment in cutout depth and/or location within
the width dimensions. Duct hole is positioned in bottom of
cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and
rear wall ducting, 6" PVC duct or locally approved piping
should be used if installing under a poured concrete slab.
Receptacle Location: Install an approved junction box
within shaded area shown in diagram. Junction box must
be at least 10-1/2" below top of cabinet.
Installation Information: Before installing, consult installation
instructions, packed with product, for current dimensional
data. Note: Electrical cable is not supplied with unit.
These cooktops are approved for indoor use only.
For answers to your Monogram,
GE Profile
®
GE
appliance questions, visit our website at
®
ge.com or call GE Answer Center
®
800.626.2000.
*U.L. Requirement.
Note: A 6" minimum spacing to adjacent side wall is required
or
service,
Cut-out Dimensions (in inches)
20-5/8
25
1-7/8"
MIN. Required*
*Note: A 6" minimum spacing to adjacent side wall is required
22
7
ʺ
29
7
16
ʺ
8
(22
ʺ SS)
9
(30ʺ SS)
16
22ʺ
20
1
ʺ
28
2
3
ʺ
4
Cabinet Dimensions (in inches)
9
28-7/8
16
20
Dimension and installation information are shown in inches.
Specification Created 7/08
2
3
ʺ
16
(2
ʺ SS)
1
4
C L
4
10-1/2
Listed by
Underwriters
Laboratories
220978

Advertisement

loading

Summary of Contents for GE GE Profile PP989DN

  • Page 1 These cooktops are approved for indoor use only. For answers to your Monogram, GE Profile ® ™ appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. ⁄ Cut-out Dimensions (in inches) 20-5/8 1-7/8"...
  • Page 2 (shown in installation instructions) for various duct configurations. For answers to your Monogram, GE Profile ® ™ appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. Through Cabinet Toe Space Between Floor Joist 6-1/8 10-1/8...
  • Page 3 • Downdraft Exhaust - Powerful exhaust system effectively pulls smoke and steam out of the kitchen • Ceramic Glass Cooktop - A smooth cooktop surface makes cleaning quick and easy • Ribbon Heating Elements - Provide powerful heat beneath a smooth glass surface to ensure even heat and fast warm-up times •...

This manual is also suitable for:

Profile pp989snProfile pp989snss