Godrej Appliances 5160 Owner's Manual

Godrej Appliances 5160 Owner's Manual

Split airconditioning system

Advertisement

PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE
INSTALLING AND OPERATING THE UNIT:
This air conditioner meets strict safety and operating
standards. The installer of this unit must install or service
this unit so it operates safely and efficiently.
IMPORTANT NOTES
• Adhere to all safety instructions and warnings
throughout this manual.
• Read this manual carefully before installing or operat-
ing this unit to become familiar with its features and
obtain the performance that will bring you continued
enjoyment for many years.
• Follow each installation or repair step exactly as
shown in the manual.
• Observe all local, state and national electric codes.
Contact your local government for more information
on electrical codes.
The lightning flash with arrowhead symbol,
within an equilateral triangle is intended to
alert the user to the presence of uninsulat-
ed dangerous voltage within the product's
enclosure that may be of sufficient magni-
tude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and main-
tenance (servicing) instructions in the liter-
ature accompanying the appliance.
Contact Installer if Necessary:
The installation instructions are for a experienced
installer. If you are not an experienced installer, contact a
local installer for help. If you require help with service,
contact your certified dealer or Daewoo Electronics for
additional instructions.
If Unit is Installed Improperly:
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this manual.
WARNING:
• ELECTRICAL SHOCK CAN CAUSE SEVERE PERSON-
AL INJURY OR DEATH. ONLY A QUALIFIED, EXPERI-
ENCED ELECTRICIAN/INSTALLER SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
• THE APPLIANCE IS NOT INTENDED FOR USE BY CHIL-
DRENOR INFIRM PERSONS WITHOUT SUPERVISION.
• YOUNG CHILDREN SHOULD BE SUPERVISED TO
ENSURE THAT DO NOT PLAY WITH THE APPLIANCE

SAFETY INSTRUCTIONS

1
Precautions When Wiring:
• Do not plug in the unit until all connections (tubing,
drain hose, mounting, etc.) have been made and dou-
ble-checked.
• High voltages are present in this unit and are very dan-
gerous. Please refer to these instructions and diagrams
when wiring. Improper connections or inadequate
grounding can cause accidental injury.
• This unit must be grounded in accordance with local
electrical codes.
• Connect wires and pipes securely and tightly as loose
connections/wiring may cause overheating at connec-
tions and a possible fire hazard.
Precautions When Transporting:
• When transporting the unit, be very careful and get help
as the units are very heavy. Be careful of sharp edges
on the units also.
Precautions When Installing:
• When installing in a ceiling or wall, make sure the
ceiling/wall is strong enough to hold the unit's weight. A
frame may be necessary for added support.
• When installing in a room, make sure the tubes are
well insulated to protect the walls and furniture from
sweating of the tubes.
• When installing in moist or uneven locations, make
sure to use a raised level concrete pad or concrete
blocks to provide a level, solid foundation for the out-
door unit; this prevents water damage and vibration.
• When installing in an area of high winds, make sure
to securely anchor the outdoor unit down with bolts and
a metal frame.
When Connecting Refrigerant Tubing:
• Keep all tubing as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of
the flare and union tubes before connecting them, then
tighten , making sure not to overtighten.
• Check the tubes carefully for leaks before starting the
test run.
When Servicing:
• Make sure the power is off and the unit is unplugged
before opening the unit to troubleshoot or repair electri-
cal parts and wiring.
• Keep your fingers and clothing away from any moving
parts.
• Clean up the sight after you finish, making sure no
metal scraps and wiring are left in the unit.
• The Air conditioner shall be installed in accordance with
the nationed wiring regulation.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5160 and is the answer not in the manual?

Questions and answers

Summary of Contents for Godrej Appliances 5160

  • Page 1: Safety Instructions

    SAFETY INSTRUCTIONS PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE INSTALLING AND OPERATING THE UNIT: This air conditioner meets strict safety and operating Precautions When Wiring: standards. The installer of this unit must install or service • Do not plug in the unit until all connections (tubing, this unit so it operates safely and efficiently.
  • Page 2: Table Of Contents

    CONTENTS It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this unit. Safety Instructions ................................1 Contents ....................................2 Basic Accessories ................................3 Optional Accessories................................4 Location of Controls................................5 Indoor Unit..................................5 Outdoor Unit .................................5 Remote Controller ................................7 Remote Display................................7 Operation .....................................8 Connecting the AC Cord ..............................8...
  • Page 3: Basic Accessories

    BASIC ACCESSORIES This Installation section explains how and where to connect this new air conditioner. Please read make sure all acces- sories are included as shown below and read manual thoroughly. This Installation section is provided to assist the per- son knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar with this type of installation.
  • Page 4: Optional Accessories

    OPTIONAL ACCESSORIES ACCESSORIES NOT SUPPLIED WITH THE UNIT: (5160 Heat Only) Description Part No. Material Size Drain Hose Extension 3103200400 ID19.6 X 2m PVC Pipe Tape 2TQ1008000 80W X 0.1T X 3.5m Copper Tubing Extension 3100002600 1/2", 1/4" Copper Tube...
  • Page 5: Location Of Controls

    LOCATION OF CONTROLS INDOOR UNIT Deodorizing Filter Removes bad smells from the air. Electrostatic Filter Emergency/ Removes dust Remote Switch Air In particles from the air. Slide to select the desired position. Indoor Cover Sensor Wire (DSB-181LH Only) Air Cleaning Remote Sensor Filters Removes dust...
  • Page 6 INDOOR UNIT Indoor Unit Display Switch Panel Remote Control Signal Receiver This place is the part to receive the signal if it receive the signal, you can hear the signal “beep. beep”. EMERGENCY REMOTE TIMER QUICK When the remote controller is lost or out- AIR CLEAN of-order, push the emergency button (EMERGENCY) to operate by hand.
  • Page 7: Remote Controller

    5160 REMOTE CONTROLLER Display AUTO Displays information pertaining to unit. ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower FAN SPEED Button the desired temperature. Press to select the fan speed (High " ", Middle " ", Low " ", FAN DIR.
  • Page 8: Operation

    OPERATION CONNECTING THE AC CORD The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the indoor unit to AC, follow the procedures below: 1. Insert the attached NOTES: AC plug into a 2- •...
  • Page 9: Celsius To Fahrenheit Conversion Chart

    CELSIUS TO FAHRENHEIT CONVERSION CHART CELSIUS FAHRENHEIT CELSIUS FAHRENHEIT 64.4 78.8 66.2 80.6 82.4 69.8 84.2 71.6 73.4 87.8 75.2 89.6 NOTES: • When operating the remote controller, make sure there are no obstructions between the remote controller and the remote sensor. •...
  • Page 10: To Set Quick Mode

    TO SET QUICK MODE To set this unit to cool or heat at the highest power, follow the procedures below: 1. Press the ON/OFF button on the remote control to 2. Press the MODE button until the Quick indicator turn the unit on; the On LED will light on the indoor blinks.
  • Page 11: To Set Fan Only Mode

    TO SET FAN ONLY MODE To operate only the fan so the unit will circulate the air, proceed as follows: 1. Press the ON/OFF button on the remote control to 2. Press the MODE button until the Fan indicator turn the unit on; the On LED will light on the indoor appears in the display.
  • Page 12: To Select The Fan Direction

    TO SELECT THE FAN DIRECTION Regardless of the mode the unit is set for, the fan direction can be changed so it moves up and down, left and right or both. Follow procedures below to set fan direction. 1. Press the ON/OFF button on the remote control to 2.
  • Page 13: To Set On Timer Mode

    TO SET ON TIMER MODE This unit can be set to automatically turn on after a predetermined amount of hours (up to 24) in the order of 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12, 16, 20, 24. 1.
  • Page 14: To Set Sleep Mode

    TO SET SLEEP MODE When you are going to sleep, select this feature and the unit will cool off the room to the desired temperature and then increase that temperature throughout the night. 1. Press the ON/OFF button on the remote control to 2.
  • Page 15: Changing/Cleaning The Air Filters

    CHANGING/CLEANING THE AIR FILTERS To change or clean the two black air filters, follow the procedures below: 1. Open the indoor unit’s 2. Remove the two small fil- cover and remove both ters (Deodorizing and black air filters by Electrostatic) from the bending them slightly indoor unit.
  • Page 16: Installing The Remote Bracket

    INSTALLING THE REMOTE BRACKET To install the remote bracket, insert one of the 2 supplied screws into top hole of the bracket and into the wall. Level the remote bracket and insert the other screw into the bottom hole. Insert the remote controller when not using it. CARE AND MAINTENANCE warning •...
  • Page 17: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Before requesting service, please refer to the chart below for possible solutions: SYSPTOMS POSSIBLE CAUSE POSSIBLE SOLUTIONS No power. Power failure. Restore the power Line voltage too low. Contact electrician to install new outlet. Unit is unplugged or not completely Insert plug all the way.
  • Page 18: Specifications

    Anti-bacteria Filter, Electrostatic Filter, Deodorizing Filter Operating Indoor side (Heating Mode) min 21˚C~max 32˚C (min 15˚C~max 27˚C) Condition Outdoor side (Heating Mode) min 21˚C~max 50˚C Design and specification are subject to change without notice for product improvemont. Godrej Appliances Ltd. Pirojshanagar, Vikhroli, Mumbai - 400079.
  • Page 19 OWNER'S MANUAL SPLIT AIRCONDITIONING SYSTEM MODEL #: 5160...

Table of Contents

Save PDF