Multiplexer Description; Multiplexer Specifications; Multiplexer Environment - Agilent Technologies E1346A Service Manual

48-channel relay multiplexer agilent 75000 series b
Table of Contents

Advertisement

Multiplexer
Description
NOTE
E1346A
Description
Multiplexer
Specifications
Multiplexer
Environment
1-6 General Information
The Agilent E1346A Single Ended Relay Multiplexer is an "instrument" in
a VXIbus mainframe. As such, the multiplexer is assigned an error queue,
input and output buffers, and a status register.
Instruments are based on the logical addresses of the plug-in modules. See
the Agilent 75000 Series B Installation and Getting Started Guide to set the
addresses to create an instrument.
The Agilent E1346A Single Ended Relay Multiplexer provides switching
(multiplexing) of up to 48 channels (i.e., channels 00 to 47). Each channel
switches only a High (H) connection. The Low (L) and Guard (G)
connections are common for all channels. The multiplexer module can only
close one channel at a time.
See Appendix A of the Agilent E1346A User's Manual for Agilent E1346A
specifications. These specifications are the performance standards or limits
against which the instrument may be tested.
The recommended operating environment for the Agilent E1346A Single
Ended Relay Multiplexer is:
Environment
Temperature
o
Operating
0
Storage and
-40
Shipment
Humidity
o
C to +55
C
<65% relative (0
o
o
C to +75
C
<65% relative (0
o
o
C to +40
C)
o
o
C to +40
C)

Advertisement

Table of Contents
loading

This manual is also suitable for:

75000 series c

Table of Contents