Do you have a question about the WS-DCADAP and is the answer not in the manual?
Questions and answers
Summary of Contents for LeCroy WS-DCADAP
Page 1
Accessory WS-DCADAP EXTERNAL DC ADAPTER User's Manual...
Page 2
WaveSurfer is a trademark of LeCroy Corporation. Windows is a registered trademark or a trademark o f Microsoft Corporation in the United States and other countries.
Page 3
Reproduction or reprinting of the contents of this manual without prior permission from LeCroy is prohibited. If you have questions about this instrument, please contact LeCroy Corporation. (Refer to the contact address given at the end of this manual.)
Page 4
WaveSurfer Accessory Checking the Packing Content On delivery of the instrument, check each item. If any of the items are missing or there is any damage, immediately contact LeCroy or the sales office in charge. [Items to be present] • DC Adapter (EXTERNAL DC ADAPTER) ........ 1 Accessories •...
(a) Mounting the DC Adapter on the Oscilloscope ......9 (b) Connecting the DC Power Cord to the Oscilloscope ....10 (c) Connecting the WS-DCADAP Cable.........11 (d) Connecting the WS-DCADAP Cable to the Battery ....13 (e) Starting Up the Oscilloscope............ 14 (f) Turning Off the Oscilloscope............ 16 (g) Turning Off the DC Adapter and the Battery ......
WaveSurfer Accessory Safety Requirements This section contains information and warnings that must be observed to keep the DC Adapter operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the safety precautions specified in this section.
Page 7
(All mains isolated terminals) Pollution Degree 2 Protection Class I CAUTION To avoid personal injury or damage to the WS-DCADAP or the WaveSurfer oscilloscope connected to it, review and comply with the following safety precautions. • Use only as intended.
Page 8
It is also important to remember not to connect a grounded device such as a computer or printer to the oscilloscope while it is floating. To connect a grounded device to the WaveSurfer oscilloscope while using the WS-DCADAP the ground cable must be connected between the oscilloscope and earth ground.
WaveSurfer oscilloscope is powered by DC Adapter. CLEANING The outside of the WS-DCADAP hardware should be cleaned with a soft cloth dampened with either deionized / distilled water or isopropyl alcohol. Allow the surface to dry completely before returning the instrument to service.
This adapter is used with it mounted on the rear of the WaveSurfer oscilloscope as shown in Fig. 1. Connect the adapter to a battery using the special input cable (WS-DCADAP cable). The input voltage supplied from a battery is converted to 24 Vdc and output to the DC IN connector at the rear of the oscilloscope.
Figure 2 shows the outside view of the adapter. Knob screw DC power cord Power switch LED lamp (green) Nameplate Input/output indication label Connector for the input cable (WS-DCADAP) Rubber foot (5 locations) Unit: mm Figure 2 Outside View of the DC Adapter...
This is an input cable specially designed for the DC adapter. Figure 3 shows the outside view of the cable. (Red alligator clip) (DC adapter side) (Battery/DC power side) (Black alligator clip) Unit: mm Figure 3 Outside View of the WS-DCADAP Cable...
EXTERNAL DC ADAPTER User’s Manual Operating Procedures To use this product, follow the steps below. (a) Mounting the DC Adapter on the Oscilloscope 1. Place the rear sides of the DC adapter and the WaveSurfer oscilloscope so that they face each other. Align the upper and lower lugs on the left side of the adapter (viewed from the rear side of the oscilloscope) with the lug holes, and then insert the lugs into the holes by sliding the adapter leftward.
WaveSurfer Accessory 3. Tighten the right and left screw knobs by hand while pressing them in to fasten the DC adapter to the oscilloscope. (See Figure 6 below.) NOTE Tighten the right and left screw knobs evenly. Screw knobs Figure 6 Fastening the DC Adapter (b) Connecting the DC Power Cord to the Oscilloscope After mounting the DC adapter on the rear of the WaveSurfer...
EXTERNAL DC ADAPTER User’s Manual (c) Connecting the WS-DCADAP Cable The WS-DCADAP cable is used to input the voltage supplied from the battery to the DC adapter. 1. Check the lug positions of the DC adapter IN jack and the WS-DCADAP cable plug.
Page 16
WaveSurfer Accessory 2. Press the WS-DCADAP cable plug into the IN jack while aligning the lug positions. (See Figure 9 below.) Figure 9 Fit of the IN Section 3. Tighten the setscrew of the WS-DCADAP cable plug around the jack screw of the DC adapter to fasten the connector. (See Figures 10a and 10b below.)
NOTE 2 Before making connections, make sure to turn off the POWER switch of the DC adapter. (Red alligator clip: + terminal) − (DC adapter side) Battery (or other DC power unit) (Black alligator clip: − terminal) Figure 11 Connecting the WS-DCADAP Cable to the Battery...
WaveSurfer Accessory (e) Starting Up the Oscilloscope After making necessary connections, start up the oscilloscope following the steps below. 1. Set the input voltage to the DC adapter. NOTE 1 Use a battery with the rated output voltage of 12 Vdc or 24 Vdc.
Page 19
EXTERNAL DC ADAPTER User’s Manual the power is automatically switched to the AC power. In such cases, a switching time of approximately 1 sec is required to switch the power inside the oscilloscope. If the AC power is connected while the DC power is being used and the DC power is turned OFF (or the cable is disconnected) at the same time, the power supply is interrupted during switching time and the...
WaveSurfer Accessory (f) Turning Off the Oscilloscope Follow the instructions in the WaveSurfer Operator’s Manual to turn off the oscilloscope (g) Turning Off the DC Adapter and the Battery After the power supply of the oscilloscope has entered the standby state, perform the terminating operation as shown below.
EXTERNAL DC ADAPTER User’s Manual Indicators If you turn on the POWER switch of the DC adapter, the (green) POWER lamp in the label goes on. POWER Green Figure 13 Status Indication of the DC Adapter...
This adapter is equipped with several protective functions for electrical specifications, temperature, etc. Table 5 shows those functions and related phenomena. If any phenomenon in Table 5 is observed, please contact LeCroy Corporation. (Refer to the contact address given at the end of this manual.) Table 5 Description of Protective Functions (1 of 2) <Protective Function>...
Page 23
Never apply a voltage exceeding the rated value. If a high voltage was applied by mistake, please contact LeCroy Corporation. NOTE1 If the input voltage to the DC adapter is interrupted instantaneously or if it exceeds the specified power supply range, the output may be stopped to protect the oscilloscope.
WaveSurfer Accessory Specifications (a) Product Specifications - Electrical Item Specifications Input voltage range 12 to 28 Vdc (at the end of the alligator clip) Input current Max 18 A (for the input voltage of 12 V) Rated power: About 150 W Input power Max: About 200 W 23.5 Vdc ±5%...
Meets intent of the European Council Directives 73/23/EEC for product safety and 89/336/EEC for electromagnetic compatibility. This declaration is based upon compliance of the WS-DCADAP to the following standards: EC Declaration EN 61326: 1997 +A3:2003 EMC requirements for electrical equipment for measurement, control, and of Conformity laboratory use.
Need help?
Do you have a question about the WS-DCADAP and is the answer not in the manual?
Questions and answers