Element Cleaning And Replacement - Kenmore 153.321511HT Owner's Manual

50 gal. endura electric water heater
Table of Contents

Advertisement

Service and Adjustment
(cont'd)
Element Cleaning/
Replacement
_,IMPORTANT
ELEMENT REPLACEMENT
INFORMATION
I
This water heater is equipped with a special element
that has 13/, ' ' threads i Hake sure that the replace-]
ment e ement has 13/, threads.
I
3. Attach
a hose to the water heater
drain
valve and put the
other end in a floor drain or outdoors. Open the water heater
drain valve. Open a nearby hot water faucet which will relieve
pressure in the water heater and speed draining,
I" DIAMETER
THREADED CAP
IW' DIAMETER
THREADED
CAP
O-RING GASKET
( IV," ELEMENT
ONLY)
NOTE: These
instructions
are written
for element
deaning
and element
replacement
for the lower element. If it is neces-
sary to clean or replace the upper dement,
then repeat these
instructions.
To remove
the element
from your tank in order
to clean or
replace it:
1. Before beginning
turn "OFF"
the electric power supply to the
water heater.
_WARNING
HAZARD OF ELECTRICAL SHOCK! Before removing
any access panels or servicing the water heater, make
sure the electrical supply to the water heater is turned
"OFF". Failure to do this could result in DEATH, SERI-
OUS BODILY INJURY,OR PROPERTY DAMAGE.
2. Turn off the water supply
to the water hearer
at the water
shutoffvalve
or water meter.
AWARNING
I
The water passingout of the drain valve may be extreme- I
ly hot. To avoid being scalded, make sure all connections
are tight and that the water flow is directed away from
any person.
4. Remove the two screws securing the access panel, and remove
panel.
5. After you have removed the lower access panel, remove the
adjustment dial from the thermostat
by gently pulling it
directly away from the thermostat.
©'/
6. Remove the insulation
block to expose the opening.
18
k. J,

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.321510ht

Table of Contents