SECTION 2 SPECIAL TEST EQUIPMENT 2.1 INTRODUCTION 2.2 SPECIAL TOOLS AND TEST EQUIPMENT 2.3.1 Test Panel and Test Harness 2.3.2 Alignment Tool Figure 2-1. Alignment Tool...
Page 13
CAUTION PARAMETER SPECIFICATION Frequency 1089.0 to 1090.0 MHz XMTR PWR 125 Watts Minimum through a –1.5dB coax Pulse Rise Time 50 nS to 100 nS Pulse Fall Time 50 nS to 200 nS Pulse Width 350 nS to 550 nS...
3.3 TESTING 3.3.1 Test Equipment 3.3.2 Test Setup 3.3.3 Test Procedure 3.3.3.1 Turn-On Delay NOTE 3.3.3.2 Reply Transmission Frequency 3.3.3.3 Transmitter Power Output...
Page 15
3.3.3.4 Minimum Trigger Level Adjustment (MTL) 3.3.3.5 Reply Pulse Characteristics EXT TRIG CH 2 VERTICAL SENS HORIZONTAL SWEEP DELAYED SWEEP XPDR MODE RF LEVEL SLS / ECHO FREQUENCY/POWER TOGGLE SWITCH PARAMETER SET POINT CH 2 (XMTR Detected Video) 20mV/Div 100ns CENTER ON FIRST PULSE PARAMETER MODE C...
Page 16
PARAMETER Rise Time: Fall Time: Pulse Width: Figure 3-2. Example Of Acceptable Reply Pulse 3.3.3.6 Dynamic Range 3.3.3.7 Automatic Overload Control (AOC) SPECIFICATION 50-100 nS 50-200 nS 350-550 nS...
Page 17
3.3.3.8 Side Lobe Suppression 3.3.3.9 External Suppression 3.3.3.10 External Altittude Encoder Inputs EXT TRIG CH 2 VERTICAL SENS HORIZONTAL SWEEP DELAYED SWEEP PARAMETER SET POINT CH 2 (XMTR Detected Video) 20MV/DIV 5µS CENTER ON FIRST PULSE...
Page 19
3.3.3.11 IDENT Test Figure 3-5. P1, P3, and SPI Pulses 3.3.3.12 Front Panel Test - OFF...
Page 20
3.3.3.13 SBY (Stand By) Set the transponder mode select switch to the SBY position. The “SBY” nomenclature and the four reply code digits shall be illuminated with a higher intensity than the “OFF”, “ON”, “ALT” and “TST” nomenclature. All internal power supplies shall be on but the unit shall not reply to any interrogations. 3.3.3.14 Set the transponder mode select switch to the ON position.
Page 21
3.3.3.17 Front Panel Test - Reply Light 1. Rotate the Mode Select Switch from TST to ALT and with the unit not replying. Increase the RF level on the ATC-1400A above MTL so that the transponder has a reply rate above 90%. The triangle-shaped reply light shall turn on.