Installation
Instructions
1. Turn
off the circuit
hreaker
(s) (30 amp)
or remove
the dryer's
circuit
fllse at ttle electrical
box.
2. Be sure ttle dwer
cold
is unphlgged
from
ttle wall receptacle.
3. Remove
tile powei
cord
covel
located
at ttle lower
back.
4. Remove
and discard
giound
suap.
Kee t) the green
ground
screw
for step
7.
5. Install
3/4 in. UL recognized
stiain
ielief
to powei
cord
entry
hole.
Bring power
cord
through
strain
relief_
6. Connect
power
cold
as follows:
A. Connect
the 2 hot lines to the outer
screws
of
tile terminal
block
(marked
L1 and L2).
B. Connect
tile neutral
(white)
line to the center
of
tile temlinal
block
(marked
N).
7. Attach
giound
wire of power
cold with the gieen
ground
screw
(hole
above
shain
relief bracket).
Tighten
all
terminal
block
screws
(3) completely.
8. Properly
secure
power
cold to strain
lelief.
9. Reinstall
the covel_
, WARNING:
NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK•
CONNECTING
DRYER USING 3-WIRE
CONNECTION
IFREQUIRED,
BYLOCAL CODE,
INSTALL E XTERNAL GROUND
(NOTPROVIDED)
TOGROUNDED
METAL, COLD WATER PIPE, OR
GREEN
GROUND
OTHER E STABLISHED
GROUND GROUND ;TRAP
DETERMINEDBYAQUALIFIED S CREW
ELECTRICIAN.
HOT
WIRE
STRAIN RELIEF
BRACKET
3/4",UL
RECOGNIZED
STRAIN RELIEF
NEUTRAL
HOT
(White) WIRE
/
COVER
3 #10AWGMINIMUMCOPPER
CONDUCTORS OR120/240V 30APOWER
SUPPLY CORD KITMARKED FOR USE
WITHDRYERS & PROVIDED W ITHCLOSED
LOOP ORSPADE TERMINALS WITH
UPTURNED E NDS (NOTSUPPLIED).
1. Turn off tile circuit
breaker
(s) (30 amp)
or remove
the dryer's
circuit
fllse at the electrical
box.
2. Be snle
the dryer
cold
is unphlgged
froin
the wall.
3. Remove
the powei
cord
cover
located
at the lower
back.
4. Install
3/4 in. UL recognized
strain
lelief
to power
cold
enhy
hole.
Bnng
powei
cord
thiough
shain
reliefl
5. Connect
power
cord
as follows:
A. Connect
the 2 hot lines to the outer
screws
of the
tenninal
block
(marked
L1 and L2).
B. Connect
tile neutral
(white)
line to the center
of
tile temlinal
block
(marked
N).
6. Be snle
ground
strap
is connected
to iletltlal
(center)
terminal
of block
and to green
glound
screw
on cabinet
real. Tighten
all terminal
block
screws
(3) completely.
7. Ploperly
secure
power
cold
to shain
reliefl
8. Reinstall
the covel.
, WARNING:
NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK•
3
[] EXHAUST
INFORMATION
_WARNING
- USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT
LONGER
THAN
SPECIFIED
IN THE
EXHAUST
LENGTH
TABLE.
Using
exhaust
longer
than specified
length
will:
• Increase
the drying
times
and the enelgy
cost.
• Reduce
tile dryer
life.
• Accmnulate
lint, cleating
a potential
fire hazard.
The
correct
exhaust
installation
is YOUR
RESPONSIBILITY.
Problems
due to incorrect
installation
are
not covered
by the warranty.
Tile MAXIMUM
ALLOWABLE
length
of the exhaust
system
depends
upon
tile type of duct, mnrlber
of turns,
the type
of
exhaust
hood
(wall cap), and all conditions
noted
below.
Both
rigid
and flexihle
metal
duct are shown
in the table
below.
EXHAUST
LENGTH
RECOMMENDED
MAXIMUM LENGTH
Exhaust
Hood Types
Use only for short
run installations
4" DIA.
Recommended
4,,
No. of 90 _
Rigid
Flexible
Rigid
Flexible
Elbows
Metal
Metal
Metal
Metal
0
90 Feet
55 Feet
60 Feet
45 Feet
1
60 Feet
40 Feet
45 Feet
30 Feet
2
45 Feet
30 Feet
35 Feet
20 Feet
3
35 Feet
20 Feet
25 Feet
15 Feet
4
25 Feet
15 Feet
15 Feet
10 Feet
If using flexible
metal
duct, please
refer to page 5.
EXHAUST
SYSTEM
CHECK LIST
HOOD OR WALL CAP
• Terminate
in a manner to prevent bar'k drafts o1"entry of birds oi
other wildlife.
• Termination
should present
minimal
resistance
to tile exhaust
air flow
and shouM requite little or no maintenance
to prevent
clogging.
• Never install a screen in or over tlle exhaust duct. This could cause lint build up.
• Wall caps must be installed at least 12 in. above ground
level or ally other
obstruction
with the opening
pointed down.
• If roof vents or louvered
plenums
are used, they inust be equivalent
to a
4-in. dampened
wall cap in regard to resistance
to air flow, prevention
of
back drafts, and maintenance
required
to prevent
clogging.
SEPARATION
OF TURNS
For best performance,
separate all turns by at least 4 ft. of straight duct,
including
distance
between
last ttlrn and exhaust
hood.
TURNS
OTHER
THAN
90 °
• One turn of 45 ° or less may be ignored.
• Two 45 ° turns should be treated as one 90 ° turn.
• Eactl turn over 45 ° shouM be treated
as one 90 ° turn.
SEALING
OF JOINTS
• All joints shouM be tigtlt to avoid leaks. Tile male end of each section of
duct must point away from ttle dryer.
• Do
not asselnble ttle ductwotk
with fasteners that extend into tlle duct.
They will serve as a collection
point for lint.
• Duct joints call be made air and moisture
tight by wrapping
the
overlapped
joints with duct tape.
• Horizontal
runs stlould slope down toward tile outdoors
1/2 inch per foot
INSULATION
Duct work that tuns ttltough an unheated
area ot is near air conditioning
shoukt be insulated
to reduce condensation
and lint build-up.