preventIve mAIntenAnCe

Every six months:
1. Be sure all electrical connections are tight.
2. Inspect antenna coaxial cable for wear or breaks in shielding.
3. Be sure all screws and mounting hardware are tight.

mAIntenAnCe

The PC687 is designed to give you years of trouble-free service. There are
no user-serviceable parts inside. Except for the fuse in the DC power cord,
no maintenance is required.
To replace a blown fuse:
1. Press ends of the fuse holder together. Twist to open. Carefully
separate the two pieces.
2. Remove the fuse and inspect. If blown, replace with the same
type fuse.
Use only the fuse specified for your PC687. Failure to do so may void your
warranty.

troUBleshootIng

In the event of system malfunction, perform the following procedures:
Problem
Unit does not power up
No reception
Poor Reception
Suggestion
Check power cord connections.
Check fuse.
Check vehicle electrical system.
Check microphone connection.
Set CB/WX/PA to CB.
Check VOL and SQ.
Check antenna.
Check antenna connection.
Adjust RF Gain.
Check VOL and SQ.
Adjust RF Gain.