Draining Procedure for Hot Water Tank and DPK CWT
This procedure is to be performed prior to transportation of unit and when converting
brewer between Pour Over usage and Direct Plumb usage.
THIS PROCEDURE MAY RESULT IN THE RELEASE OF
WATER AT TEMPERATURES HOT ENOUGH TO RESULT IN
BURNS. DRAINING PROCEDURE SHOULD ONLY BE
PERFORMED BY TRAINED SERVICE PERSONNEL.
1. Disconnect the brewer from AC power and, if applicable, disconnect the Direct
Plumb Unit from water supply.
2. On rear of brewer locate Access Panel and remove securing screw.
3. Lower the appropriate tube, remove Plug and drain into appropriate sized
container. NOTE: Hot Water Tank contains ~ 31 oz of water, Cold Water Tank
contains ~ 35 oz of water.
4. Replace Plugs and Access Panel.