MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the
illustration in these installation instructions.
INSTRUCTIONS D'INSTALLATION
DE L'ENSEMBLE FOUR
MICRO-ONDES/HOTTE
Ce produit est congu pour I'utilisation au-dessus d'appareils de cuisson 61ectriques ou _.gaz de 36" (91,4 cm) de largeur
ou moins.
Ces instructions d'installation sont valables pour plusieurs modules. II se peut que I'apparence de votre propre module soit
16g_rement diff6rente de celle montr6e sur les illustrations dans ce document.
Table of Contents / Table des mati@res
OVEN SAFETY ..................................................
2
.....................................
2
...........................................
3
Tools and Parts ......................................................................
3
Location Requirements ..........................................................
4
Product Dimensions ...............................................................
4
Electrical Requirements .........................................................
5
.............................................
5
Remove Mounting Plate .........................................................
5
Rotate Blower Motor ..............................................................
5
Locate Wall Stud(s) ................................................................
7
Mark Rear Wall .......................................................................
8
Drill Holes in Rear Wall ...........................................................
8
Attach Mounting Plate to Wall ...............................................
9
Prepare Upper Cabinet ..........................................................
9
Install Damper Assembly .....................................................
10
Install the Microwave Oven ..................................................
10
Complete Installation ...........................................................
12
ASSISTAN CE ...........................................................................
12
Replacement PaRs ...............................................................
12
Accessories ..........................................................................
12
13
13
EXIGENCES D'INSTALLATION ..........................................................
15
Outillage et pi_ces ............................................................................
15
Exigences d'emplacement
...............................................................
15
Dimensions du produit .....................................................................
16
16
...................................................
17
D_pose de la plaque de montage ....................................................
17
R_orientation
du moteur du ventilateur ...........................................
17
Identifier la position du/des poteaux du colombage mural ............. 19
Trac_ sur le mur arri_re ....................................................................
20
Pergage de trous dans le mur arriere ...............................................
20
Fixation de la plaque de montage sur lemur ..................................
21
Preparation du placard mural ...........................................................
22
Installation du module du clapet anti-reflux .....................................
22
Installation du four & micro-ondes
...................................................
22
Achever I'installation .........................................................................
24
ASSISTANCE .......................................................................................
24
Pi_ces de rechange ..........................................................................
24
Accessoires ......................................................................................
24
IMPORTANT: Read Installation Instructions thoroughly before beginning installation. Save Installation Instructions for local house
inspector's use.
IMPORTANT : Liser completement
les instructions d'installation
avant de commencer I'installation. Conserver ces instructions
d'installation & I'usage de I'inspecteur local des installations de la maison.
8205144

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool 8205144

  • Page 1: Table Of Contents

    IMPORTANT: Read Installation Instructions thoroughly before beginning installation. Save Installation Instructions for local house inspector's use. IMPORTANT : Liser completement les instructions d'installation avant de commencer I'installation. Conserver ces instructions d'installation & I'usage de I'inspecteur local des installations de la maison. 8205144...
  • Page 2: Microwave Oven Safety

    MICROWAVE OVEN SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 3: Installation Requirements

    Rectangular to Round Transition 31/4 '' x 10" (8.3 x 25.4 cm) vent system = 73ft (22.2 m) total NOTE: The minimum 3" (7.6 cm) clearance must exist between the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
  • Page 4: Electrical Requirements

    Parts Supplied Special Requirements For reorder information, see "Replacement Parts" section. NOTE: The hardware items listed here are for wood studs. For For Wall Venting Installation Only: other types of wall structures be sure to use appropriate fasteners. • The 12" x 4" (30.5 x 10.2 cm) cutout area must align with the rectangular hole in the mounting plate.
  • Page 5: Installationinstructions

    GROUNDING INSTRUCTIONS [] For all cord connected appliances: The microwave oven must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. The microwave oven is equipped with a cord having a grounding wire with a grounding plug.
  • Page 6: Rotate Blower Motor

    Roof Venting Installation Only 1. Repeat Step 1 from "Wall Venting Installation Only," 2. Repeat Step 2 from "Wall Venting Installation Only," 3. Repeat Step 3 from "Wall Venting Installation Only." 4. Repeat Step 4 from "Wall Venting Installation Only," 5.
  • Page 7: Install The Microwave Oven

    bscc e Stud(s} NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within install the microwave oven, the opening. See illustrations in "Possible Wall Stud Configurations," 2.
  • Page 8 Wall Venting Installation Only The microwave oven must be installed on a minimum of 1 wall Centerline Upper Cabinet Bottom stud, preferably 2, using a minimum of 1 lag screw, preferably 2 or more. 1. Using measuring tape, find and clearly mark the vertical centerline of the opening.
  • Page 9 Afi csch Moun One Wall Stud at Two Corner Holes (Figure 3) NOTE: Secure the mounting plate to the wall at all 4 corner holes 1. With the support tabs of the mounting plate facing forward, drilled into the wall studs and/or drywall using either 1/4-20 x 3" insert 1/4-20 x 3"...
  • Page 10 5. Cut the 11/2"(3.8 cm) diameter hole at the circular shaded area "G" on the template. This hole is for the power supply cord. ! sto!! tse Mic eve Oven NOTE: If upper cabinet is metal, the supply cord bushing needs to be installed around the supply cord hole, as shown.
  • Page 11 If adjustment is required, rotate microwave oven downward. Using 2 or more people, lift microwave oven off of mounting For Roof Venting Installation Only plate, and set aside on a protected surface. 1. Insert damper assembly through the cabinet cutout so that the long tab of the damper assembly slides under the raised tabs of the damper plate.
  • Page 12: Assistance

    ASSISTANCE Comple st<sllcAion Refer to the Use and Care Guide for instructions on how to install filters into your model. Call your authorized dealer or service center. When you call, you will need the microwave oven model number and serial number. Both numbers can be found on the model and serial number plate, which is located behind the microwave oven door on the front frame of the microwave oven.
  • Page 13: Securite De L'ensemble Four .& Micro-Ondes/Hotte

    SECURITE DE L'ENSEMBLEFOURA MICRO-ONDES/HOTTE Votre s_curit_ et celle des autres est tr_s importante. Nous donnons de nombreux messages de securite importants dans ce manuel et sur votre appareil menager. Assurez-vous toujours lire tousles messages de securite et de vous y conformer. Ce symbole d'alerte de securite vous signale les dangers potentiels de deces et de blessures graves a vous et &...
  • Page 14 Raccord de transition rectangulaire/rond Longueur recommand_e du circuit d'6vacuation REMARQUE : On doit disposer d'un espace libre de 3" (7,6 cm) ou plus entre le sommet du four & micro-ondes et le raccord de On devrait utiliser un conduit rectangulaire 31/4 '' x 10" (8,3 x transition rectangulaire/rond pour que le clapet anti-reflux puisse 25,4 cm), ou un conduit rond de dia.
  • Page 15: Exigences D'installation

    EXIGENCES D'INSTALLATION Mat_riaux n_cessaires • Composants standard pour decharge a travers lemur ou travers le toit Voir la section "Specifications/conception circuit d'evacuation'. Outillage n_cessaire Rassembler les outils et pieces necessaires avant de commencer I'installation. Lire et suivre les instructions fournies avec les outils mentionnes ici.
  • Page 16: Specifications

    Dimensions & respecter Iors de I'installation REMARQUE : La prise de courant &3 alveoles reli_e & la terre dolt _tre situee & I'int_rieur du placard mural. Voir la section "Specifications _lectriques". Risque de choc electrique Brancher sur une prise a 3 alveoles reliee a la terre.
  • Page 17: Instructionsd'installation

    INSTRUCTIONSD'INSTALLATION Retirer deux vis fixant le moteur du ventilateur de I'arriere du four a micro-ondes. Retirer de la cavite du four a micro-ondes tousles articles qui peuvent s'y trouver. Enlever la plaque de montage : enlever les morceaux de ruban adhesif fixant la plaque de montage sur la face arriere du four micro-ondes et mettre la plaque de montage de c6te.
  • Page 18 Fixer a nouveau le moteur du ventilateur & I'arriere du four & 6. Fixer & nouveau le moteur du ventilateur a I'arriere du four & micro-ondes avec 2 vis 6t_es a I'etape 3. micro-ondes avec 2 vis 6tees a I'etape 3 de la section "Pour une installation avec decharge murale seulement"...
  • Page 19 REMARQUE :S11n'ya auoun poteau du colombage dans lazone I. Utiliser un d@tecteur magn@tique de clou/vis p our looaliser d@limit@e p ar l'ouverture dans leplacard mural, ne pas installer dans l'euverture lesrives des poteaux du colembage mural. foura micre-ondes. 2. Marquer laposition d u centre de chaque poteau du Voir les illustrations &...
  • Page 20: Trac_ Sur Le Mur Arri_Re

    Pour une installation avec d_charge murale seulement Le four & micro-ondes doit 6tre fixe sur au moins un poteau du colombage mural, et de preference sur 2 poteaux; on utilise pour cela au moins 1 vis d'ancrage, et de pref6rence 2 vis ou plus. Axece[._ Fondd_cardeup_rieur 1.
  • Page 21: Pergage De Trous Dans Le Mur Arriere

    Pousser les 4 vis avec ecrou articule & travers le panneau de gypse; visser les visa la main pour verifier que chaque _crou Deux trous des angles en coincidence avec un poteau articule s'est deploye et prend appui contre le panneau de du colombage (Figure 3) gypse.
  • Page 22 Quatre trous des angles en coincidence avec les Pour une installation avec d_charge & I'ext_rieur travers le toit seulement poteaux du colombage (Figure 4) 1. Positionner la plaque de montage sur le mur; veiller ace que 7. Decouper un trou de 3/4" (19 mm) dans un coin de la zone le sommet de la plaque de montage soit aligne avec la rive ombr_e rectangulaire "F"...
  • Page 23 REMARQUES 3. Faire intervenir 2 personnes ou plus pour soulever le four & micro-ondes et le suspendre aux pattes de support situees en • Certaines configurations du placard mural necessitent bas de la plaque de montage. I'emploi de vis plus Iongues ou plus courtes que 3" (7,6 cm). REMARQUE : Durant I'installation, ne jamais prendre prise sur la Acheter les vis necessaires plus Iongues ou plus courtes dans porte ou la poignee de la porte.
  • Page 24: Assistance

    Pour I'information relative au depannage, consulter le Guide d'utilisation et d'entretien. L'installation est maintenant terminee. Conserver les instructions d'installation pour une eventuelle reutilisation future. 8205144 4619-656-01312 7/05 © 2005. All rights reserved. Printed in China Tous droits reserves. Irnprirn_ en Chine...

Table of Contents