HOW TO ADJUST THE DOOR GAP

If the gap between the left and right fridge
compartment doors is not even.
• You can adjust the gap by turning
the bolt at the top right of the cold
storage compartment door.
• Do not turn the bolt too far.
You can break it.
1. With the doors closed, remove the 3 screws
holding the top cover using a Phillips
screwdriver, and then lift it off together with the
connected cables.
2. Turn the bolt with a 4 mm
hexagonal L-wrench to adjust
the gap. (Not provided)
3. Turn the bolt clockwise to
(
) widen the gap.
Turn the bolt counter clockwise (
the gap.
INSTALLING THE WATER
DISPENSER LINE
A water dispenser with a filter is one of the helpful
features on your new refrigerator. To help promote
better health, the water filter removes unwanted
particles from your water. However, it does not
sterilize or destroy microorganisms. You may need
to purchase a water purifying system to do that.
The water line also connects to the ice maker.
For the ice maker to operate properly, water
pressure of 20~125 psi (138~862 kPa) is required.
If the refrigerator is installed in an area with low
water pressure (below 20 psi), you can install a
booster pump to compensate for the low pressure.
After you have connected the water line, make
sure the water storage tank inside the refrigerator is
properly filled. To do this, press the water dispenser
lever until the water runs from the water outlet.
14_ setting up
DA68-02918A-01.indb 14
• Water line installation kits are available at
extra cost from your dealer.
We recommend using a water line
installation kit that contains copper
tubing and ¼" compression nut.

Connecting to the water supply line

1. First, shut off the main water
supply.
2. Locate the nearest cold water drinking line and
install the pipe clamp and shut off valve.
3. Connect the water line installation kit to the shut
off valve.
Cold water line
) to narrow
Pipe clamp
Shut off valve
Connecting the water supply line to the
refrigerator.
There are several items that you need to purchase
to complete this connection.
You may find these items sold as a kit at your local
hardware store.
For Copper Tubing
• ¼" copper tubing
• ¼" compression nut (1pc)
• Ferrule (2pc)
Cold water line
Pipe clamp
Shut off valve
Water line installation kit
For Plastic Tubing
• ¼" plastic tubing
→ Molded end(Bulb)
• ¼" compression nut (1pc)
13. 4. 25.