High
MAIC
Efficiency Air Cleaner
Manual for:
Installation
• Operation
i
Maintenance
MAIC0014A
& MAIC0020A
Literature # 616 01 1004 02
1.o7

Advertisement

loading

Summary of Contents for ICP MAIC0014A

  • Page 1 MAIC Efficiency Air Cleaner High Manual for: Maintenance Installation • Operation • MAIC0014A & MAIC0020A Literature # 616 01 1004 02 1.o7...
  • Page 2: Safety Considerations

    NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installation and service of heating and air conditioning equipment can be hazardous due to system pressure and gas and electrical components. Only trained and qualified personnel should repair, or service heating and air conditioning...
  • Page 3 iNTRODUCTiON The Model MAIC High Efficiency Air Cleaner is designed for installation in the return= air duct in any forced-air heating and/or cooling system. The model MAIC High Efficiency Air Cleaners are available in two sizes, 0014 and 0020. The FMC media filter isa mechanical air cleaner incorporating special pleated filter media designed to remove dirt, dust, pollen, and other microscopic particles from the air passing through it.
  • Page 4: Specifications

    I I \",,,l I )/_ I//TN'M I J//qN",d "N_I ],//I I \_ D=T= =1 === A ===_ Model Number MAIC0014A MAIC0020A 600-1600 600-2000 Air Flow (CFM) Range Dimensions 7 1/8" (181mm) 7 1/8" (181mm) 24 7/8" (632mm) 24 7/8" (632mm) 16 3/8"...
  • Page 5 AiR FLOW RESISTANCE Typical Pressure Drop Mode! Number Air Flow (CFM) MAIC0014A MAIC0020A Resistance (in. w.c.) 1000 1200 1400 1600 1800 2000...
  • Page 6 TYPICAL MOUNTING POSiTiONS MEDIA AIR CLEANER BASEMENT FURNACE COUNTERFLOW FURNACE SPACE SAVER FURNACE (LOWBOY) Mounted horizontally in return Mounted horizontally in return (HIGHBOY) Side installation. Cleaner is plenum - just above the furnace duct - just above the furnace mounted vertically, where return air enters side inlet of furnace.
  • Page 7 APPLiCATiON The air cleaners are used in forced air heating, cooling and ventilating systems. The air cleaner should be installed in the system so that all the system air is circulated through the air cleaner. The air cleaner will only remove the airborne contaminants delivered to it.
  • Page 8 Turning Vanes Ifthe air cleaner is installed adjacent to a 90 ° duct elbow, add turning vanes inside the duct to improve the air distribution across the face of the air cleaner (Figure 3). Figure 3 - Turning Vanes Humidifiers Location of the system humidifier is important to the operation...
  • Page 9: Physical Installation

    SELECT LOCATION FOR THE AiR CLEANER Select a location that is readily accessible for periodic inspection and cleaning. Allow a minimum of 26" in front of the access panel for filter removal. For complete dimensions required, refer to the section entitled SPECiFiCATiONS.
  • Page 10 NOTE: Thefollowing is a typical installation of the air cleaner on a high boy furnace. You may have to alter the installation to fit your specific application. 5. Locate the cabinet in the cold air return duct so that all of the return air flows through the unit.
  • Page 11 HOW TO MAINTAIN YOUR AIR CLEANER The filter in your air cleaner must be replaced periodically. The frequency of filter replacement is best determined by visual examination. average, media filters should be replaced every 6-12 months under normal usage. STEPS FOR REPLACING FILTER 1.
  • Page 12 Five=Year Limited Cabinet Warranty This product is warranted to be free from defects in material and workmanship for a period five years from the date of original installation, whether actual use begins then or later, If the product fails during the warranty period, a new or remanufactured...