Download Print this page

Frymaster Super Cascade Filtration Systems CE Operation Manual page 11

Frymaster super cascade filtration systems operation manual

Advertisement

Enter from
page 8 here.
Plug is in the bottom of the
filter pan or in the line from the
filter to the pump.
Disconnect the tubing from
the filter pan to the motor.
Make sure the pipe is cool.
Can you blow air
through it?
Yes
The line is clear.
Reconnect hose to the
pump inlet.
Turn pump ON.
Does oil flow?
Yes
Conduct normal
filter operations.
Contact your
Factory
Authorized
Servicer.
NEVER USE A PROPANE TORCH
TO
SHORTHENING IN ANY PART OF
THE SYSTEM.
USING AN OPEN FLAME NEAR
COMBUSTIBLES.
HAZARD IS
No
The line is clogged.
Run a cable through the
line to clear clogs.
Continue until you can
blow air through it.
There may be a plug in
No
the oil return line
system.
Disconnect the oil return line
running from the pump to the oil
return valve. Clean the pipe to
remove residual shortening.
Disconnect the oil return line
running from the oil return valve
to the frypot. Clean the pipe to
remove residual shortening.
Reconnect the oil
return lines.
Turn pump ON.
No
Does oil flow?
Conduct normal
filter operations.
9
DANGER!
MELT
SOLIDIFIED
YOU WOULD BE
THE
EXTREME!
Yes
FIRE

Advertisement