Samsung SGH-E300 Service Manual page 15

Gsm telephone
Hide thumbs Also See for SGH-E300:
Table of Contents

Advertisement

SGH-E300 Flow Chart of Troubleshooting and Circuit Diagrams
2. DCS RX
NORMAL CONDITION
catch the channel?
YES
F900 CHECK
pin8 ≥ -65dBm ?
YES
F900 CHECK
pin4,5 ≥ -65dBm ?
YES
U800 CHECK
pin18, 19 ≥ -65dBm ?
YES
U800
pin 9, 32: 2.8V ?
YES
U800 CHECK
pin 8 : 13MHz ?
Vp-p : 950mV?
YES
U800
pin1,2,3,28 Vp-p
: 120mV ?
YES
U701 CHECK!!
NO
CHECK
ANT701,L905 contact ?
NO
C900, F901
resolder or change
NO
F900
resolder or change
NO
C914,C915,L902
resolder or change
NO
U102 pin39, C112
change or resolder
NO
OSC801
change or resolder
NO
U800
resolder or change
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
2-12