Gsm Receiver - Samsung SGH-Q100 Service Manual

Dual band mobile cellular phone
Hide thumbs Also See for SGH-Q100:
Table of Contents

Advertisement

5-11. GSM Receiver

RX On
RF input : 62 CH
Amp. : -50 dBm
U1006
Pin 9
-70 dBm
U1006
Pin 9
-70 dBm
F1004
pin 5
-73 dBm
U901
pin 4
&
F901
pin 4
-60 dBm
F902
pin 1, 2
-55 dBm
F902
pin 7, 8
-60 dBm
U901
pin 43, 44
-50 dBm
END
Y
Y
N
Y
Y
-55 dBm
2.5Vdc
Y
Y
N
Y
Y
N
Y
SAMSUNG Proprietary-Contents may change without notice
SGH-Q100 Flow Chart of Troubleshooting and Circuit Diagram
•All or RF values by dBm should be measured in max hold status of
RF spectrum analyzer in active call
Resolder or Change CN301
N
Resolder U1006,
Pin 5
-70 dBm?
Y
N
Resolder or Change U901
N
Resolder or Change F901
N
Check OSC901
pin 1
-20 dBm
Y
N
Check OSC902
pin 1
-20 dBm
Y
5-11
Check voltage
U1006 pins
Pin 2 : L
N
Pin 4 : H
Pin 8 : H
Pin 10 : L
Resolder
F1004
Change OSC901
N
Resolder or
Change U901
Change F902
Resolder or change
N
OSC902
Change U901