Valor Fires VALORFIRES 847 Installer And Owner Manual

Dimension electric firefront

Advertisement

INSTALLER AND OWNER GUIDE
Model
Fitted with one of the following fascia:
Classica, Dream, Innova
And for use with the
(GC No. EF-032-40)
This guide is intended to help you
install and care for your Valor Fires
Electric Firefront. Please read
carefully before installing and using
your firefront. However, if further
information is required, our
Valor Fires Technical Helpline will
be pleased to help.
Telephone
0844 8711 565
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone
0044 844 8711 565.
Important: Please keep your guide in a safe place for future reference.
©
Baxi Heating U.K. Limited 2009.
847 Dimension
Baxi Bermuda BBU15 HE
(National
Electric Firefront.
Regalia.
or
5135238/02
Boiler.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VALORFIRES 847 and is the answer not in the manual?

Questions and answers

Phil
February 12, 2025

How to replace bulb in electric fire model 847

Phil
February 12, 2025

How to replace bulb

Summary of Contents for Valor Fires VALORFIRES 847

  • Page 1 Telephone 0844 8711 565 (National call rates apply in the United Kingdom). In the Republic of Ireland Telephone 0044 844 8711 565. Important: Please keep your guide in a safe place for future reference. © Baxi Heating U.K. Limited 2009.
  • Page 2 Applications for the copyright owner's permission to reproduce any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, The Wyvern Business Park, Stanier Way, Derby, DE21 6BF.
  • Page 3 INSTALLER GUIDE INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 17 TO 31 © Baxi Heating U.K. Limited 2009. Page 3...
  • Page 4: Table Of Contents

    Method B - Securing with wire using an Optional Spacer Frame kit 6. FITTING THE FASCIA Fitting the Dream fascia. Fitting the Classica fascia. Fitting the Regalia fascia. Fitting the Innova fascia. 7. REMOVING THE FASCIA AND FIREFRONT © Baxi Heating U.K. Limited 2009. Page 4...
  • Page 5: Installer Guide

    Always grip with the palm of the hand. Do not use the tips of fingers for support. Always keep the firefront as close to the body as possible. This will minimise the cantilever action. Use gloves to provide additional grip. Always use assistance if required. © Baxi Heating U.K. Limited 2009. Page 5...
  • Page 6: Safety

    CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. © Baxi Heating U.K. Limited 2009. Page 6...
  • Page 7: Optional Kits

    (Illustrations are not to scale) Spacer frame 1 ONLY No 8 x 3/8 Self- tapping screws Figure 1. Model Spacer kit number Model Spacer kit number Classica 5135632 Innova 5135632 Regalia 5135633 Dream 5135634 © Baxi Heating U.K. Limited 2009. Page 7...
  • Page 8: Pack Contents

    No. 8 x 3/8 pan head screw Tension wire Eye screw ‘AAA’ Battery Cable clamp Handset M4 x 25mm screw Washer Nylon Grommet Figure 2. Contents (Continued on next page - Fascias not shown)) © Baxi Heating U.K. Limited 2009. Page 8...
  • Page 9: Fitting The Firefront

    This prevents the cable being trapped under the firefront during installation. Fit the cable clamp as in figure 3. Figure 3. Fitting the cable clamp © Baxi Heating U.K. Limited 2009. Page 9...
  • Page 10: Do I Need Any Tools

    To check the shelf clearance gently place the fascia against the surface to which it is to be fixed and measure the distance from the top of the fascia. © Baxi Heating U.K. Limited 2009. Page 10...
  • Page 11: Securing The Firefront

    ‘click’ into place. Place the firefront in front of the boiler, connect the Boiler Control lead to the lead on the boiler and check the boiler operation. Figure 5. Fitting the Boiler Control. © Baxi Heating U.K. Limited 2009. Page 11...
  • Page 12 10. Locate the firefront in the fireplace opening, then from the front of the firefront, gently pull the steel wire on the right hand side to gather up the excess until the © Baxi Heating U.K. Limited 2009. Page 12...
  • Page 13: Method B - Securing With Wire Using An Optional Spacer Frame Kit

    No.8 x 3/8 screws supplied (See figures 8 and 2). 3. Continue with the installation as in points 3 to 10 of method A. Figure 8. Fitting the optional spacer frame to the firefront © Baxi Heating U.K. Limited 2009. Page 13...
  • Page 14: Fitting The Fascia

    Figure 10. Fitting the Classica fascia those on top of the firefront (See figure 10). Lower the fascia into place and swing the bottom of the fascia towards the firefront to engage the magnets. © Baxi Heating U.K. Limited 2009. Page 14...
  • Page 15: Fitting The Regalia Fascia

    (See figure 12). Lower the fascia into place and swing the bottom of the fascia towards the firefront to engage the magnets. Figure 12. Fitting the Innova fascia. © Baxi Heating U.K. Limited 2009. Page 15...
  • Page 16: Removing The Fascia And Firefront

    With the end of the wire free, gently pull the firefront forward. 3. After completing work on the boiler fit the firefront and fascia as in sections 5 and 6 of this guide. © Baxi Heating U.K. Limited 2009. Page 16...
  • Page 17: Owner Guide

    OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 26 TO 31 © Baxi Heating U.K. Limited 2009. Page 17...
  • Page 18 If you require further assistance, the Valor Fires Technical Helpline will be pleased to help. Please telephone 0844 8711 565 (local rates apply in the United Kingdom). In the Republic of Ireland please telephone 0044 844 8711 565. © Baxi Heating U.K. Limited 2009. Page 18...
  • Page 19: Operating The Firefront

    Pressing the red ‘ON/OFF’ button. Pressing this button at any time whilst the effect and heater are in operation will turn the effect and heater off. Figure 2. lamp locations © Baxi Heating U.K. Limited 2009. Page 19...
  • Page 20: Manual Control - What Is It And Why Is It There

    Press the button a fourth time. Pressing this button at any time whilst the effect or heater are in operation will turn the effect and heater off. © Baxi Heating U.K. Limited 2009. Page 20...
  • Page 21: To Light And Reset The Boiler

    How to switch the Boiler ON. 1. If the boiler is OFF, open the hinged panel that covers the Boiler Control. Press the On / Off button on the Boiler Control for half a second. © Baxi Heating U.K. Limited 2009. Page 21...
  • Page 22: How Do You Know When The System External Controls Are Requesting Heating Or Hot Water

    In this case, a waiting time of 5 hours is required to recover one further reset attempt. After 4 reset attempts we recommend that you contact Heateam on 0844 8711 565. When contacting heateam it will help to quote the error code that has been displayed. © Baxi Heating U.K. Limited 2009. Page 22...
  • Page 23: How To Switch The Boiler Off

    (error code) indicates a fault. Please see Troubleshooting section on opposite page. If an error code is persistently displayed consult your installer or a qualified GAS SAFE REGISTER engineer, (CORGI or GAS SAFE REGISTER outside of UK). © Baxi Heating U.K. Limited 2009. Page 23...
  • Page 24: Important Safety

    Alternatively a cut out device is fitted to the firefront to prevent damage due to over heating. If it operates due to an obstruction in the airflow, the firefront must be turned off and allowed to cool for 15 minutes and the obstruction removed before restarting. © Baxi Heating U.K. Limited 2009. Page 24...
  • Page 25: Environment

    What should I do when I’m ready to dispose of my firefront? The plug should be removed from the mains cable and the mains cable cut from the firefront. These should be disposed of with the firefront. © Baxi Heating U.K. Limited 2009. Page 25...
  • Page 26: Warranty And Service

    To activate your second year free warranty you must register your boiler and firefront with heateam, the service division of Baxi Heating UK Ltd, either by completing and returning the registration card or calling our telephone registration line on 0800 032 7230.
  • Page 27 Compensation or consequential losses (e.g. loss of earnings, business losses, stress and inconvenience) arising from a production breakdown, including repair delays caused by factors outside our reasonable control. © Baxi Heating U.K. Limited 2009. Page 27...
  • Page 28 OWNER GUIDE © Baxi Heating U.K. Limited 2009. Page 28...
  • Page 29 OWNER GUIDE © Baxi Heating U.K. Limited 2009. Page 29...
  • Page 30 Boiler Serial number (Can be found on the information label - See figure 6) A LABEL CONTAINING THE BOILER SERIAL NUMBER MAY HAVE BEEN PLACED INSIDE THIS BOX. Date of Installation Figure 6 © Baxi Heating U.K. Limited 2009. Page 30...
  • Page 31: Owner Guide

    Firefront Fascia code - Can be found close to the information label (Block Capitals) A LABEL CONTAINING THE FASCIA CODE MAY HAVE BEEN PLACED INSIDE THIS BOX. Brand (Please tick) Baxi Valor Wonderfire Other......Date of Installation Figure 7 © Baxi Heating U.K. Limited 2009. Page 31...
  • Page 32 © Baxi Heating U.K. Limited 2009.

Table of Contents