Baxi Solarflo Installation Manual page 5

Solar thermal domestic hot water system
Hide thumbs Also See for Solarflo:
Table of Contents

Advertisement

Fig. 3
Solarflo - Solar Thermal Domestic Hot Water System
3.0
Hydraulic station specifications
3.1
Technical data
Dimensions
(Height/Width/Depth)
Flow and return connections
(compression fittings)
Maximum working temperature:
Maximum working pressure:
Pressure Relief Valve setting:
Circulating Pump:
Circulating Pump voltage:
Power consumption Setting 1:
Setting 2:
Setting 3:
Maximum Pump Head:
Maximum Pump Capacity:
Flow meter scale:
375/250/190mm
22mm
120°C
6 bar
6 bar
Grundfos UPS 25-60
/ Wilo ST 25/6
230/240 V ~
45W / 45W
68W / 65W
90W / 85W
6 metres
4.5 m
3
/h / 3.5 m
3
/h
2 to 15 l/min