WARRANTY
Bacharach, Inc. warrants to Buyer that at the time of delivery this Product
will be free from defects in material and manufac ture and will conform
substan tially to Bacharach Inc. ' s applicable specifi cations. Bacharach's
liability and Buyer's remedy under this warranty are limited to the repair
or replacement, at Bacharach's option, of this Product or parts thereof
returned to Seller at the factory of manufacture and shown to Bacharach
Inc. ' s reason able satisfaction to have been defective; provided that written
notice of the defect shall have been given by Buyer to Bacharach Inc.
within one (1) year after the date of delivery of this Product by Bacharach,
Inc. For full details concerning this warranty, contact Bacharach Inc.
World Headquarters
621 Hunt Valley Circle, New Kensington, PA 15068
Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 800-736-4666
Website: www.mybacharach.com • E-mail: help@mybacharach.com
Printed in U.S.A.
®Registered Trademark

Advertisement

loading
Need help?

Need help?

Do you have a question about the DRAFT GAUGE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bacharach DRAFT GAUGE

  • Page 1 Inc. ’ s reason able satisfaction to have been defective; provided that written notice of the defect shall have been given by Buyer to Bacharach Inc. within one (1) year after the date of delivery of this Product by Bacharach, Inc. For full details concerning this warranty, contact Bacharach Inc.
  • Page 2: Mounting The Instrument

    For portable use, check zero each time the gauge is set up for use. For permanent installations (always dis- connect the hose from the gauge before making the zero check) Figure 1. Draft Gauge check zero at one or two week intervals.
  • Page 3 Parts List for the Draft Gauge 0013-0014 Scale +.05 <0> –.25” H 0013-0015 Scale +.05 <0> –1.0” H 0013-0016 Scale +1 <0> –25mm H 0013-0017 Scale +1 <0> –5mm H 0013-0159 Scale +1 <0> –15mm H 0013-0056 Leaf Spring Assembly for +.05” <0> –.25” or +1 <0> –5mm H...
  • Page 4: Measuring Draft

    Figure 4. Draft Gauge Locations Measuring Draft Figure 3. Mounting Draft Gauge Allow furnace to operate for several minutes, unwrap hose, place Locations for Checking Draft gauge on reasonably level surface, check zero, insert metal draft tube through draft hole. After about 30 seconds read draft from Furnace manufacturer may require measurement of draft (a) in gauge scale.