  • Page 1 SMARTLEVE[ Digital Electronic Level Owner's Manual...
  • Page 2: Table Of Contents

    One-Year Limited Warranty Warranty Registration Inside Front cover If, within one year from the date of original purchase, the Smartlevel Sensor Module or rail(s) Smartlevel: Digital Electronic Level fail to function because of defects in materials or workmanship, Wedge Innovations ("Wedge")
  • Page 3: Smartlevel: Digital Electronic Level

    Mode button (Shift-Range) at the same time (see pages 12 reset feature allows you to easily recalibrate SmartLevel to and-13). original accuracy. Set the base of SmartLevel upon the surface you wish to measure. The display automatically shows the angle in clear, easy-to-use numbers. RAIL & SENSOR MODULE...
  • Page 4: Smartlevel Features

    SmartLevel Features Mode Button Selecting Smartlevel Functions Choosing the Measurement SmartLevel is easy to use. Each button controls the feature -· that's written on it (ON/OFF, MODE, RESET, and HOLD). nn n In addition, the Mode button works like a shift key to access I HOLD I 00.0...
  • Page 5 Wait 1 0 seconds, and note the angle on the display. • Rotate the level end-for-end so the display is on the opposite side. Be sure and set Smartlevel in exactly the same spot, and allow it to sit for at least 1 0 seconds before reading the angle again.
  • Page 6: Reset

    • Wait 15 seconds flow to Perform SuperSet • Press Reset button, hold until flashing Turri on SmartLevel and place it on a flat surface. You can "CAL 1" symbol appears briefly, followed by flashing angle measurement use any horizontal surface within 10° of level and any verti- cal surface within 10°...
  • Page 7: Superset Horizontal Settings

    ..r'" ,.., ..""1 ""1 L.C~ L. 0 -• • Flip Smartlevel over so the narrow top of • Rotate Smartlevel so that Sensor rail is against vertical suface and Sensor Module faces away from you Module faces away from you •...
  • Page 8 1/10 (.1) of a degree; the (±) symbol"1" will appear on the Hold button while SmartLevel is reading the angle that you display are measuring. The readout will freeze and a flashing "H" will appear on the right side of the display. To release, press Range "2"...
  • Page 9: Measuring With Smartlevel

    CAUTION: If you set your SmartLevel to read 0.0° when it is off level, The SmartLevel display electronically "flips over" when the you must follow the Reset procedure before you can once again accurately...
  • Page 10: Integrated Wall Stand-Offs

    Finally, we added large handholds for the entire rail length, allow- pressure, the cams may still be engaged. Use the screwdriver to turn the cams ing you to get a firm, safe grip on your SmartLevel, even when while pushing the module out. wearing work gloves.
  • Page 11 •Install or remove the battery. • Replace the cover and snug the screws. Don't forget to RESET your Smartlevel after reinstalling the module. DO NOT OVERTIGHTEN. (See pages 7·11) Low Battery Power Indicator When the battery is weak, the SmartLevel displays the "Low Battery"...
  • Page 12: Smartlevel Maintenance

    See Mode Button, page 5-6; below -20°C (-4°F) or higher than 60°C (140°F). or Hold/Range Button, • Don't forget to RESET your Smartlevel daily, and to use the simple "end- pages 12-13. for-end" test frequently to see if SUPERSET is required.
  • Page 13 WEDGE N t \ : O V A T O N S Wedge Innovations 2040 Fortune Drive, Suite 102 Jose, California 95131 -9799 Phone: 1-800-SMARTLEVEL (762-7853) '""ova!~s S!rnrtloo. Sna1 Tools ard Superset are re!)'~ered 1992 Wedge Wed;je lnr<JVa:1ons, tradenwl<s .';! 'Wedge lnrmat.m...