Patton electronics 3080/V24 Installation And Operation Manual

Digital sharing device

Advertisement

Quick Links

Doc #: 124001UA
B
Part #: 07M3080-A
D
S
D
IGITAL
HARING
EVICE
3080/V24
(CTS DSD-8)
I
O
M
NSTALLATION AND
PERATIONS
ANUAL
August 23, 2000
An ISO-9001
Copyright© 2000 Patton Electronics Co., All Rights Reserved
Certified Company

Advertisement

Table of Contents
loading

Summary of Contents for Patton electronics 3080/V24

  • Page 1 Doc #: 124001UA Part #: 07M3080-A IGITAL HARING EVICE 3080/V24 (CTS DSD-8) NSTALLATION AND PERATIONS ANUAL August 23, 2000 An ISO-9001 Copyright© 2000 Patton Electronics Co., All Rights Reserved Certified Company...
  • Page 2 3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA PROPRIETARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by Patton Electronics Co.
  • Page 3 Anhang 2 zur Anlage 1 zur AmtsblVfg 243/1991 Bescheinigung des Herstellers / Importeurs Hiermit wird bescheinigt, daß der/die/das 8 Port Digital Sharing Device, 3080/V24 (CTS DSD-8), 124000 (Gerät, Typ, Bezeichnung) in Übereinstimmung mit den Bestimmungen der BMPT-AmtsblVfg 243/1991 funkentstört ist.
  • Page 4: Table Of Contents

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA Table of Contents CHAPTER 1 - OPERATION Channel Clocking..........................1-1 Channel Interface ..........................1-1 Anti-streaming............................ 1-2 Channel Selection Modes ......................... 1-3 Channel Tail Circuits ......................... 1-4 Interface Connections ........................1-4 Front Panel LEDs ..........................1-4 Channel Enable / Disable Switches ....................
  • Page 5: Chapter 1 - Operation

    Sub-Channel 6 RX Clock (pin 17). Channel Interface The 3080/V24 (CTS DSD-8) has nine DB-25 female connectors located on the rear of the unit. Each connector is pinned with EIA RS-232, using RS-423 electrical characteristics. This enables extended cable driving distances, which often bypasses the need for line drivers.
  • Page 6: Anti-Streaming

    Manual Anti-Stream - If manual Anti-Stream protection is chosen, a streaming condition caused by one of the attached terminals can be quickly corrected by the 3080/V24 (CTS DSD-8) via the associated front panel locking switches. A switch is provided for each Sub- Channel and permits the rapid removal of a streaming terminal without having to disconnect any cables or power down the offending terminal.
  • Page 7: Channel Tail Circuits

    Sub-Channel become active that Sub-Channel is switched through to the master port by the 3080/V24 (CTS DSD-8). All remaining Sub-Channels are locked out until the first device becomes inactive. When the Sub-Channel device becomes inactive, the 3080/V24 (CTS DSD-8) will resume scanning the Sub-Channels for another active signal.
  • Page 8: Interface Connections

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA Interface Connections All connections are made via industry standard EIA RS-232 DB-25 female connectors located on the rear of the unit. The following interface leads are implemented, Chassis (1), TXD (2), RXD (3), RTS (4), CTS (5), DSR (6), Sig Gnd (7), DCD (8), Plus Unreg (9), Minus Unreg (10), TXC (15), RXC (17), DTR (20), XTXC (24).
  • Page 9: Chapter 2 - Setup And Installation

    CHAPTER 2 - SETUP AND INSTALLATION Power Connection Before connecting the 3080/V24 (CTS DSD-8) to a AC power source the top cover must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/220VA voltage switch, turn the switch with a coin or screw driver to the appropriate voltage for your country.
  • Page 10: Disassembly

    “PORT 1” on the rear panel of the 3080/V24 (CTS DSD-8). Secure other terminals or Modems to be serviced to the remaining “PORT” connectors. Connect the MODEM or TERMINAL to the connector designated “MASTER DTE/DCE”.
  • Page 11: Cts Delay (Sw31-3,4,5)

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA CTS Delay (SW31-3,4,5) If a CTS delay is desired, set SW31-3, 4 and 5 to the required value as indicated below. SW31-3 SW31-4 SW31-5 Time No Delay 1 m S 2 m S...
  • Page 12: Control Turn-Off Delay In "Data" Switching Mode (Sw29-1,2)

    The value selected is the number of clocks at the current baud rate that must occur without any data transitions on the Sub-Channel to indicate that Sub-Channel has completed its transmission and the 3080/V24 (CTS DSD-8) can resume servicing the other Sub- Channels. The following table should be used to set this time period.
  • Page 13: Fallback Clock Enable (Sw-30-6)

    NOTE: Both TX and RX Clock Source Select MUST Be Set !!!! TX Clock Source Selection (SW27--1,2,3) TX Clock Source is selected by switch SW27-1, 2 and 3. The following table indicates the source options provided by the 3080/V24 (CTS DSD-8). SW27-1 SW27-2...
  • Page 14: Rx Clock Source Selection (Sw28-1,2,3)

    RX Clock Source Selection (SW28-1,2,3) RX Clock Source is selected by SW28-1, 2 and 3. The following table indicates the source options provided by the 3080/V24 (CTS DSD-8). NOTE: If TXC Source is pin 24 That clock will be used as the RXC also.
  • Page 15: Port Dce/Dte Selection (Sw9 Thru Sw26)

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA Port DCE/DTE Selection (SW9 thru SW26) Slide switches SW9 through SW26 are used to configure DTE/DCE for each port. Slide Both switches associated with a port to the same position. Example: If connecting a modem (DCE Device) to the PORT, then the port should be configured as a DTE interface.
  • Page 16: Dtr / Dsr Forced Active (Jp6 Thru Jp14)

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA DTR / DSR Forced Active (JP6 thru JP14) DTR is tied to DSR on each of the Sub-Channel ports. If the device connected does not supply a DTR but requires DSR (DTE) or does not supply DSR but requires DTR (DCE), installing the forced DTR/DSR jumper (JP6-JP14) for the appropriate Sub-Channel will solve this problem.
  • Page 17: Appendix

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA APPENDIX RS-423 RS-423 RS-423 Leased Leased Dial Line Dial Line RS-423 MODEM RS-423 MODEM RS-423 RS-423 RS-423 Leased Dial Line 3080/V24 RS-423 MODEM 3080/V24 Typical Application Modem Modem Host Modem Terminal Modem 3080/V24...
  • Page 18: Master Dte / Sub-Channel Dte Interface Flow Diagram

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA Master DTE / Sub-Channel DTE Interface Flow Diagram Master DTE / Sub-Channel DCE Interface Flow Diagram PPENDIX...
  • Page 19: Master Dce / Sub-Channel Dte Interface Flow Diagram

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA Master DCE / Sub-Channel DCE Interface Flow Diagram Master DCE / Sub-Channel DTE Interface Flow Diagram PPENDIX...
  • Page 20: Technical Specifications

    3080/V24 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 124001UA TECHNICAL SPECIFICATIONS Applications Sub-Channel Interface Multiple Sync or Async DCE or DTE devices EIA RS-232 female connectors (DB-25) using sharing one DCE or DTE link RS-423 electrical characteristics. Capacity Modem Interface One to Eight Sync or Async DTE or DCE...
  • Page 21 Port 1 Port 3 Port 5 Port 7 Port 2 Port 4 Port 6 Port 8 Master JP6 thru JP14 Force DTR/DSR Active When Installed SW10 SW11 SW12 SW13 SW14 SW15 SW16 SW17 SW18 SW19 SW20 SW21 SW22 SW23 SW24 SW25 SW26 RX Cl ock Source SW28 MASTER Source...
  • Page 22 7622 Rickenbacker Drive Gaithersburg, MD 20879 Sales: 301 975-1000 Support: 301 975-1007 Web Address: www.patton.com...