Wheelock AIM-3 Installation Instructions Manual

Auxiliary input module

Advertisement

Quick Links

273 Branchport Avenue
Long Branch, NJ 07740
(800) 631-2148
www.wheeelockinc.com
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
Model Numbers:
AIM-3
107387
Auxiliary Input Module
General:
The AIM-3 is an outboard expansion module for use with the SAFEPATH control panels to expand the number of optional Remote
Microphones (RM) from 1 to 3. The module is compatible with all SAFEPATH panels and Remote Microphones. The PCB
assembly is mounted in an enclosure.
READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT.
NOTE: All CAUTIONS and WARNINGS are identified by the symbol
SAFE
NOTE: Up to 3 Remote Microphones or up to 2 Remote Microphones and a telephone page port, may be connected to a SAFEPATH
Panel with an AIM-3.
NOTE: When using the AIM-3 for telephone paging on a SAFEPATH panel that is using Remote SAFEPATH panels for strobe
activation, the strobe circuits connected to the Remote SAFEPATH's will activate during a telephone page.
Copyright 2003 Wheelock, Inc. All rights reserved.
AIM-3 Manual
Rev. C July 2003
Thank you for using our products.
INSTALLATION INSTRUCTIONS
AUXILIARY INPUT MODULE
RM
PORT
PA T H
PA NEL
Basic Capabilities of the AIM-3
. All warnings are printed in bold capital letters.
RM
INPUT
PORT 1
PORT
AIM-3
RM
PORT 2
RM
PORT 3
Figure 1.
REMOTE
MICROPHONE
1
REMOTE
MICROPHONE
2
REMOTE
MICROPHONE
3
OR
TELEPHONE
PAGING
P83667 C
Sheet 1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIM-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wheelock AIM-3

  • Page 1 General: The AIM-3 is an outboard expansion module for use with the SAFEPATH control panels to expand the number of optional Remote Microphones (RM) from 1 to 3. The module is compatible with all SAFEPATH panels and Remote Microphones. The PCB assembly is mounted in an enclosure.
  • Page 2: Technical Specifications

    Operating Temperature 0° to +49° C, 32° to 120.2 ° F Storage Temperature -20° to 70° C, -4° to 158° F Humidity 85±5% @ 30±2° C Non-condensing Installation: AIM-3 Manual P83667 C Rev. C July 2003 Sheet 2 of 12...
  • Page 3: Installation Guidelines

    Handle the board by its edges, and be careful not to twist or flex it. The AIM-3 is to be installed in a static free area and the user is to properly attach grounded wrist straps before touching any static sensitive areas.
  • Page 4: Wiring Guidelines

    The shield of each cable should be connected only at one end. Each shield of each cable that connects to the AIM-3 is to connect to the grounding points provided near the right edge of the chassis (see Figure 2).
  • Page 5 CONDUIT KNOCKOUTS 2 PLACES, BOTH ENDS 6.00" MOUNTING HOLES GROUND TERMINALS 11.00" MOUNTING HOLES Figure 2. AIM-3 Mounting NOTE: Drawing is not to scale. AIM-3 Manual P83667 C Rev. C July 2003 Sheet 5 of 12...
  • Page 6 Wiring Diagram with up to 3 Remote Microphones NOTE: If the AIM-3 is configured for less than 3 Remote Microphones, the +/- RM AUDIO terminals of the unused Remote Microphone port must be terminated with the supplied listed 10K ohm 1/4W resistor.
  • Page 7 Telephone Input Applications: The AIM-3 can be connected to an unused CO Port, a page port, an analog station port ( with TPI-100 ) or to a zone control (MCZ- 144 ). When it is used for telephone paging, it should only be used for telephone paging only and not for background music. The VOLUME adjust is used to set the telephone page volume.
  • Page 8 AIM-3 SWITCH CONFIGURATION: ANALOG STATION PORT SWITCH POSITION AUDIO ZONE 1 AUDIO MZEM-3 BOARD ONE WA Y ZONE CENTRAL A MP SEL. 1, SEL. 2 ON AS NEEDED ZONE A RXD/CC SEL. 3 POWER PHONE -24VDC RM/PHONE PHONE RMS-3 OF A IM-3...
  • Page 9 Operation: The AIM-3 polls the Remote Microphone stations to determine supervision and alarm status. Any trouble condition will light the amber LED. Follow the trouble shooting procedures if the LED is lit. The first Remote Microphone that is selected will have priority over the other two.
  • Page 10 PHONE SEL3 SEL2 SEL1 AUDIO POWER AUDIO POWER AUDIO POWER AUDIO RXD/CC POWER TB 4 PEAK Figure 8. AIM-3 Board Layout AIM-3 Manual P83667 C Rev. C July 2003 Sheet 10 of 12...
  • Page 11: Troubleshooting

    TROUBLESHOOTING: While AIM-3 is connected and powered up, switch SW1 positions SEL. 1, 2, 3 and PHONE to OFF. Switch ON as to be cofigured. Ve rify 1. Check +/- power connection from SAFEPA T H Panel to AIM-3. Power to 2.
  • Page 12: Limited Warranty

    (as determined by date code). Correction of defects by repair or replacement shall be at Wheelock's sole discretion and shall constitute fulfillment of all obligations under this warranty. THE FOREGOING LIMITED WARRANTY SHALL IMMEDIATELY TERMINATE IN THE EVENT ANY PART NOT FURNISHED BY WHEELOCK IS INSTALLED IN THE PRODUCT.

Table of Contents