Viking BLK-4 Product Manual

Viking BLK-4 Product Manual

Line status led strobe/beacon light kit

Advertisement

Quick Links

Designed, Manufactured and Supported in the USA
VIKING
C O M M U N I C A T I O N & S E C U R I T Y S O L U T I O N S
The BLK-4 provides high visibility indication of analog line
status through a high powered 360º LED strobe and/or
beacon visual indicator. The BLK-4 is the ideal solution
for the hearing impaired and can be used equally well in
loud warehouses or factories, where ringing phones can
not be heard. Alternatively, the BLK-4 can be used to add
emergency notification to pre-existing emergency phones
by turning on the strobe light when the emergency phone
is in use.
The included control module has a disable input which is
ideal for two-button emergency phones, such as Viking's
E-1600-20A, allowing "Info" button calls to be placed with-
out activating the relay (turning on the emergency strobe
light, camera, etc.) Four DIP switches are provided for
turning ring detection on or off, off-hook/loop detection on
or off, 12VDC or dry relay contact output and for selecting
a ring cadence mode which allows the relay to follow ring-
ing or to remain activated during the off time of standard
ring cadence. The control module can be installed on any
standard telephone line or analog PABX/KSU station. The
strobe can be interfaced to flash on ringing, off-hook or a
combination of ringing and off-hook (line in-use).
The BLK-4 is designed for indoor applications. The BLK-
Features
• BLK-4-EWP's control module and strobe light come
with Enhanced Weather Protection (EWP), EWP prod-
ucts are designed to meet IP66 Ingress Protection
Rating, see DOD# 859
• Durable polycarbonate lens
• High output long life LED technology
• Four programmable flash patterns:
- Single Flash
- Quad Flash
• 6 programmable beacon and strobe brightness set-
tings
• Immune to shock and vibration
• Flush mount or surface mount with weatherproof sin-
gle gang box (included)
• 3/4" knockouts for connecting conduit, etc.
• Strobe and control module may be installed separately
• Can be configured to signal: ringing, off-hook, a com-
bination of both ringing and off-hook (line in-use), or
triggered from a contact closure
• One set of (NO) normally open and (NC) normally
closed relay contacts provided
• Selectable ring cadence mode (strobe light will remain
flashing between rings)
• Switched 12V DC output (follows relay activation for
powering strobe lights, cameras, etc.)
• On/off switches for ring detection and off-hook/loop
detection
• Disable input, ideal for use with two-button emergency
phones like Viking's E-1600-20A (DOD# 215), will not
activate strobe light on "Info" calls
PRODUCT MANUAL
Provide LED Strobe / Beacon
Visual Indication of Line Status
- Double Flash
- Flicker Flash
4-EWP is equipped with Enhanced Weather Protection
(EWP) for outdoor installations where the unit is exposed
to precipitation or condensation. For more information,
see DOD# 859.
The kit includes: (1) control module, (1) SL-2/SL-2-EWP
blue LED strobe light, (1) 12V DC power adapter, (16) gel-
filled butt connectors and (1) single gang weatherproof
mounting box with gaskets and hardware.
Applications
• Ringing Phone or TTY indication for the hearing im-
paired
• Ringing phone indication in loud warehouses and fac-
tories
• Emergency illumination for emergency phones in ele-
vators, campuses, hallways, parking ramps, etc.
• Alarm indication for security systems or alarm panels
with phone dialers
Specifications
Power: 120V AC to 12V DC adapter provided
Maximum Power Supply Run Length on CAT-5: 1 pair = 125 ft,
2 pair = 225 ft, 3 pair = 325 ft, 4 pair = 475 ft
Maximum SL-2 Wire Run Length on CAT-5: 3 wires = 100 ft, 6
wires = 300 ft
Strobe Dimensions: 111mm diameter x 69mm (4.38" x 2.75")
Control Module Dimensions: 74mm x 53mm x 25mm (2.9" x 2.1"
x 1.0")
Shipping Weight: 1.5 kg (3.3 lbs)
Operating Temperature: -26° to 54°C (-15° to 130° F)
Relay Contact Rating: .5A @ 125V AC/1A @ 30V DC
Minimum Loop Current: 15 mA
Minimum Ring Voltage: 25V RMS
Ringer Equivalence: 0.5 A REN
Disable/Info Switch Input: 50mA/80mW maximum
Strobe Flash Rate: 60 flashes per minute (default) see Strobe
Flash Patterns page 6
Humidity - BLK-4: 5% to 95% non-condensing
Humidity - BLK-4-EWP: up to 100% condensing
Mounting: Fasten to wall, post, etc. with complete surface mount-
ing hardware included
Connections: Color coded wires with gel-filled butt connectors
BLK-4/EWP
Line Status LED Strobe/
Beacon Light Kit
April 17, 2013

Advertisement

Table of Contents
loading

Summary of Contents for Viking BLK-4

  • Page 1 Alternatively, the BLK-4 can be used to add emergency notification to pre-existing emergency phones by turning on the strobe light when the emergency phone is in use.
  • Page 2 Wiring IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges. Internal View of the Weatherproof Single Gang Box (included) * Gel-Filled Butt...
  • Page 3: Installation

    B. Front Mounting Without Weatherproof Box 2.75” Wall, post, etc. The BLK-4 Strobe Light Kit may be mounted without using the included weatherproof box. To mount the strobe light from the front, use the diagram shown to the right.
  • Page 4 Programming the BLK-4 Control Module A. DIP Switches BLK-4 Control Module Switch 2 Ring Cadence Mode (see section C) Ring Cadence Mode ON - relay remains activated in between rings. Ring Cadence Mode OFF - relay is activated only dur- ing ringing.
  • Page 5: Trigger Input

    “Info” button will not activate the strobe light. This way, only the “Help/Emergency” outbound calls will activate the relay. Cut one of the “Info” switch wires in half and connect each end to the blue wires on the BLK-4 control module as shown in the diagram at the right.
  • Page 6: Accessing The Programming Mode

    Strobe (See Strobe Flash Patterns, section D). Note: The SL-2 is factory default programmed as a steady on beacon with a single flash strobe when activated. The beacon and strobe are set to their brightest settings. All programming should be done prior to connecting to the BLK-4 control module. A. Accessing the Programming Mode (Optional, the SL-2 is factory programmed to the Beacon/Strobe Mode and brightest Beacon/Strobe settings).
  • Page 7: Operation

    C. Programming Features List Feature # : Description: Beacon/Strobe (factory default) Strobe Only Beacon Only Strobe Brightness 1-6 (factory default = 6/Brightest setting) Beacon Brightness 1-6 (factory default = 6/Brightest setting) Single Flash Strobe (factory default) Double Flash Strobe Quad Flash Strobe Flicker Flash Strobe Reset to Factory Default Settings D.
  • Page 8: Warranty

    Product Support: (715) 386-8666 Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

This manual is also suitable for:

Blk-ewp

Table of Contents