Silver King SKBD105P Technical Manual And Replacement Parts List

Advertisement

Quick Links

Replacement Parts List
1600 Xenium Lane North, Minneapolis, MN 55441-3787
Phone (763) 923-2441
FORM NO. 36549 REV A
Technical Manual
and
Beverage Dispenser
MODEL
SKBD105P/BK
1
Specifications Subject to Change Without Notice.

Advertisement

Table of Contents
loading

Summary of Contents for Silver King SKBD105P

  • Page 1 Technical Manual Replacement Parts List Beverage Dispenser MODEL SKBD105P/BK 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (763) 923-2441 FORM NO. 36549 REV A Specifications Subject to Change Without Notice.
  • Page 2: Technical Manual

    Please read this manual and the accompanying warranty information before operating your new Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to validate your warranty. Upon delivery of your new Silver King unit, inspect the carton and unit for shipping damages. Report any damage immediately to the transportation carrier and file a written freight damage claim to protect your investment.
  • Page 3: Operation

    After loading the creamer, press and hold the REFILL button for 3 seconds until the indicator flashes 00. Defrost: The Silver King cream dispenser is a manual defrost unit. The unit should be defrosted whenever the walls accumulate Indicator Panel a frost bank that is 1/2 inch thick.
  • Page 6 WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS...
  • Page 7: Cleaning And Refilling Procedures

    Cleaning and Refilling Procedures Removing Valve Insert To remove the valve insert once the beverage container is empty, simply press on the valve slide and remove the valve insert by pulling it straight up. Cleaning Once removed, the valve can be cleaned with a brush and warm soapy water or in a dishwasher.
  • Page 8 Cleaning and Refilling Procedures Install Container and Bag Place container inside cabinet and guide tube through valve area. Be sure the tube is straight and centered to avoid kinking, which could result in reduced product flow or leaking. Install Valve Insert Push and hold valve slide while inserting the valve insert from above.
  • Page 9: Troubleshooting Guide

    Troubleshooting Guide Complaint Cause Solution 1. No voltage at wall receptacle 1. Check circuit breaker or fuse 2. Service cord pulled out of wall 2. Replace receptacle 3. Contact power company and 3. Low voltage causing confirm that voltage compressor to cycle on fluctuation does not exceed overload 10% plus or minus from the...
  • Page 10: Ordering Parts/Service

    1. Remove valve and pull tube Beverage 2. Valve stuck straight through valve area leaking or not 2. Clean valve and valve area or flowing call for service Ordering Parts/Service Contact Silver King Refrigeration at 800-328-3329 for technical assistance. Model__________________ Serial No.___________________ Date Installed__________________...