Download Print this page

Honeywell 3252 User Manual

Wiring guidelines

Advertisement

Quick Links

L
W
ON
ORKS
Wiring Guidelines
HONEYWELL CABLE 3252, 3253, 1061,
AK3797, AK3798, AK3799
INTRODUCTION
The Free Topology Transceiver (FTT) supports polarity
insensitive, free topology wiring. This frees the system
installer from wiring using a specific bus topology. T-tap, star,
loop, and mixed wiring topologies are all supported by this
architecture. Free topology wiring reduces the time and
expense of system installation by allowing the wiring to be
installed in the most expeditious manner. It also simplifies
network expansion by eliminating restrictions on wire routing,
splicing, and device placement.
A FTT network may comprise multiple segments (L
Bus sections containing from one to sixty devices, each
device having a Neuron® ID to validate) separated by
physical layer repeaters or routers.
FTT networks are very flexible and convenient to install and
maintain, but it is imperative to carefully plan the network
layout and create and maintain accurate documentation. This
will aid in compliance verification and future expansion of the
FTT network. This will also minimize unknown or inaccurate
wire run lengths, node-to-node (device-to-device) distances,
node counts, total wire length, inaccurate repeater/router
locations, and misplaced or missing terminations.
APPLICATIONS
Free topology architecture allows the user to wire the control
devices with virtually no topology restrictions.
Unlike bus wiring designs, the FTT system uses a free
topology wiring scheme that supports T-tap, star, loop, mixed,
and/or daisy-chain (see Fig. 1). This design has many
advantages. First, the installer is free to select the method of
wiring that best suits the installation, reducing the need for
advanced planning and allowing last minute changes at the
installation site. Second, if installers have been trained to use
one style of wiring for all installations, free topology
technology can be introduced without requiring retraining.
Third, retrofit installations with existing wiring plans can be
accommodated with minimal, if any, rewiring. This capability
ensures that FTT technology can be adapted to both old and
new projects, widening the potential market for FTT based
products. Finally, free topology allows FTT systems easy
future expansion by tapping into the existing wiring where it is
most convenient to do so. This reduces the time and expense
of system expansion, and from the customers' perspective,
keeps down the life cycle cost of the free topology network.
® Bus
W
ON
ORKS
DEVICE
DEVICE
DEVICE
TERMINATION
MODULE
SINGLY TERMINATED
DEVICE
TERMINATION
MODULE
DEVICE
STAR
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
TERMINATION
MODULE
MIXED
TERMINATION
Fig. 1. Typical wiring topologies
supported by the FTT System.
USER'S GUIDE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
MODULE
DEVICE
DEVICE
LOOP
M12197
Put Bar Code Here
74-2865—04

Advertisement

loading

Summary of Contents for Honeywell 3252

  • Page 1 ® Bus ORKS Wiring Guidelines HONEYWELL CABLE 3252, 3253, 1061, AK3797, AK3798, AK3799 USER’S GUIDE INTRODUCTION DEVICE DEVICE The Free Topology Transceiver (FTT) supports polarity insensitive, free topology wiring. This frees the system DEVICE DEVICE DEVICE DEVICE TERMINATION installer from wiring using a specific bus topology. T-tap, star,...
  • Page 2 ® BUS WIRING GUIDELINES ORKS System expansion is simplified by the use of physical layer NOTES: repeaters and routers. The Q7740A 2-Way or Q7740B 4-Way — There can be no more than one repeater on either devices perform a repeater function, and the Q7751A side of a Q7751A router.
  • Page 3 See Table 2 for singly terminated FTT network bus topology transmission specifications. — See Tables 3 and 4 for a list of Honeywell provided FTT daisy-chain and free topology network wire/cables. — See the generic cable manufacturer information that meets Echelon LonWorks Bus specifications in Table 5.
  • Page 4 Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 Honeywell GmbH Böblinger Straße 17 D-71101 Schönaich customer.honeywell.com ® U.S. Registered Trademark © 2008 Honeywell International Inc. 74-2865—04 K.K. Rev. 11-08...

This manual is also suitable for:

32531061Ak3797Ak3798Ak3799Lonworks bus 3252 ... Show all