Page 38
So follwing valid IDM exist: Label Value Description Waldorf Microwave 2 System Exclusive Specifications, -------------------------------------------------- Software release 2.09 SNDR Sound Request SNDD Sound Dump 1. General SNDP Sound Parameter Change *************************************************** MULR Multi Request Sys-Ex dumps and requests will always be in the MULD Multi Dump following form:...
Page 39
------------------------------------------------ Or in case of All Sounds Dump: Index Label Value Description Index Label Value Description --------------------------------------------------- ------------------------------------------------ Marks Start of SysEx Marks Start of SysEx Waldorf Electronics Waldorf Electronics GmbH ID GmbH ID Microwave 2 ID Microwave 2 ID Device ID Device ID here MULR (Multi...
Page 40
The actual Format is: 2.41 WCTR *************************************************** Index Label Value Description WCTR Wave Control Table Request ----------------------- --------------------------- Marks Start of SysEx Upon reception of a valid wave control table request, Waldorf Electronics the MW2 will dump the selected Table. The location is GmbH ID given in two bytes with following conventions: Microwave 2 ID...
Page 41
2.51 GLBR 2.61 DISR *************************************************** *************************************************** WCTR Global Parameter Request DISR Display Request Upon reception of a valid Global Parameter request, Upon reception of a valid Display Request request, the the MW2 will dump the Global Parameters. No location MW2 will dump the contents of the LCD. No location is is given.
Page 42
2.64 DISL 2.81 MODR *************************************************** *************************************************** DISL LCD Recall MODR Mode Request Upon receprion of a Display Recall message, the LCD and the LEDs will be updated in order to discard a The full format of a MODR Dump is: possibly previously dumped LCD content.
Page 43
3. Data Formats 3.1 SDATA - Sound Data ***************************************************************************** Note: All Parameters marked as "reserved" should be set to 0 for future compatibility. Index Range Value Parameter ---------------------------------------------------------------------------------- Sound Format Version, currently 1, Format 0 is unpublished 16-112 -4...+4 Osc 1 Octave in Steps of 12 52-76 -12..+12 Osc 1 Semitone...
Page 47
3.14 Modifiers ***************************************************************************** Index Operand Operation ----------------------------------------------------------------------------- Addition Subtraction Multiplication Division Bitwise exclusive-or Bitwise inclusive-or Bitwise and S&H Sample & Hold Ramp Switch Abs value Min value Max value Lag processor Control filter Differentiator ----------------------------------------------------------------------------- ***************************************************************************** 3.15 Filter 1 Types ***************************************************************************** Index Filter Type...
Page 48
3.3 IDATA - Instrument Data ***************************************************************************** Index Range Value Parameter ----------------------------------------------------------------------------- Sound Bank 0-127 1..128 Sound Number 0-17 global,omni,1-16 MIDI Channel 0-127 0..127 Volume 16-112 -48..+48 Transpose 0-127 -64..+63 Detune Main Out/Sub Out Output off/on Status 0-127 left64..center..right63 Panning off/on/inverse Pan Mod reserved reserved...
Page 49
Device family member code, see below VV,VV,VV,VV, Software revision, ASCII, e.g. "2.09" Device family member codes (XX,YY): 00,00 Microwave 2 01,00 Microwave 2 with XT Mainboard (has Delay Effects !) 03,00 Microwave XT 05,00 Microwave PC on Terratec EWS Frontmodule *****************************************************************************...
Page 50
2.82 INFR ******************************************************************** INFR Information Request This only works for Microwave PC on Terratec EWS Frontmodule ! The full format of a INFR Dump is: Index Label Value Description ----------------------------------------------------------- Marks Start of SysEx Waldorf Electronics GmbH ID Microwave 2 ID...