The following instructions are intended for the installer so
that the installation and maintenance procedures may be
followed in the most professional and expert manner
possible.
Important: Disconnect the appliance from the
electrical supply before performing any maintenance
or regulation upkeep work.
Installation of Built-in Cooktops
The appliance can be installed next to cabinets which are
not higher than the cooktop itself. The following precautions
must be observed for proper installation:
a) If the cabinet(s) located next to the cooktop are higher
than the cooktop itself, the cabinet(s) must be installed
at least 110 mm from the edge cooktop;
b) Hoods must be installed in accordance with the
instructions contained in the installation manual for the
hoods themselves, and no less than 650 mm from the
cooktop;
c) The cabinets installed next to the hood must be located
at a height of at least 420 mm from the top.
d) Should the cooktop be installed directly under a
cupboard, the latter should be at least 700 mm
(millimetres) from the top, as shown in figure.
600mm min.
e) The dimensions of the cutout for the appliance must
be those indicated in the figure. Clamps are provided
to fasten the cooktop to counters measuring from 20
to 40 mm in thickness. To fasten the cooktop securely,
it is recommended that all the clamps be used.
55
mm

Installation Instructions for built-in

555
mm
Fastening Clamps - Assembly Diagram
Clamp Position for
H=20mm top
Clamp Position for
H=40mm top
N.B: Use the clamps contained in the "accessory kit."
f) In the event the cooktop is not installed above a built-
in oven, a wood panel must be inserted as insulation.
This panel must be placed at least 20 mm from the
bottom of the cooktop itself.
Important: When installing the cooktop above a built-in
oven, the oven should be placed on two wooden strips; in
the case of a joining cabinet surface, remember to leave
a space of at least 45 x 560 mm at the back.
When installing the cooktop above a built-in oven without
forced ventilation, ensure that there are air inlets and
outlets for ventilating the interior of the cabinet adequately.
8
Clamp Position for
H=30mm top
Front
Back