Trillium Talk To 308 Installation Manual

Electronic key telephone system
Hide thumbs Also See for Talk To 308:

Advertisement

.
.
: .
----
>I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Talk To 308 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trillium Talk To 308

  • Page 1 ---- >I...
  • Page 2: Table Of Contents

    Table of Contents FCC Requirements and Warnings Introduction Preparation Pre-installation Requirements Installation KSU Installation ................. Station Wiring Method 1 ............Station Wiring Method 2............Central Office/PABX Line Connection........Music Input ................Paging Output ................. Door Answer Option ............... Power Failure Transfer Option..
  • Page 3: Fcc Requirements

    FCC rules prohibit the use of this telephone in the the responsibility of users requiring service to report the following locations: need for service to Trillium Telephone Systems or to one of their authorized agents. a) Coin telephones. All new and existing coin-operated...
  • Page 4 2) Any telephone made available at the work station of a hearing-impaired employee for use by that employee in his or her employment duty. An employee’s “work station” is defined as the location within a workplace where that employee is usually found in the course of his or her employment duties.
  • Page 5: Introduction

    INSTALLATION Introduction This manual details the procedures to install and program the TalkTo 308 Electronic Key Telephone System. A section on Troubleshooting is also included. Installation is easy, and can be carried out by a cer- tified installer, using standard cable runs and modular jacks;...
  • Page 6: Installation

    INSTALLATION Installation The KSU contains no user adjustable controls or parts. All switches used during programming are acces- si ble at the exterior of the KSU. An indicator on the left side of the KSU flashes when the system is up and running..
  • Page 7 INSTALLATION c Stations 10-17 Program 1 Program 2 - Not Used - - PFUC Battery- - Page Out Status Indicator - - Music In Reset Push Button - - Door - co 3 - co 1.2 12.68” (31 lmm) Ground Lug 11.36”...
  • Page 8: Station Wiring - Method 1

    INSTALLATION Station Wiring - Method 1 You are now ready to connect the -KSU to the <- C.O./PABX lines. This method uses standard station wiring equip- ment such as: 625 type four-wire jacks Method 2 Wiring Table communication cable - two pair, twisted, 24 AWG wire. modular telephone Iine’cords.
  • Page 9 INSTALLATION STA 17 STA 17 6 Stations Total 6 Stations Total STA 10 Plug Plug 4 Conductor Modular Line Cords 308 KSU Communication Cable Pair 625 625 Type Type Jack Jack #12 AWG 1 IOV AC T 4 Conductor Modular Line Cord Supplied with Set Jack T I I 428...
  • Page 10 INSTALLATION 25 Pair Cable Proto Tel S66-MI-50R Block PM8-25ST4- I Jack Jack STA 10 STA 10 Plug 2 Pair Communication Cable P\n ir ir 308 KSU 625 Type Jack #I2 AWG Plug K----. Supplied with Set 4 Wire Modular Line Cords 11OV AC 0’...
  • Page 11: Central Office/Pabx Line Connection

    INSTALLATION Central Off ice/PABX Line Connection These lines are normally terminated by RJllC type jacks. When requesting service from the telephone com- pany, please request that the first two lines are terminated with an RJ14C type jack. Alternatively, if the lines are already installed using RJllC type jacks, an adapter such as an SE 2678 (Suttle Apparatus Corp.) will be required.
  • Page 12 INSTALLATION Door Answer Option The TalkTo 308 System will provide door signaling and 2 way conversation with up to 2 doors. To provide this option, one door answer unit and a maximum of 2 door modules are required. 1.57” (40mm) 3.89”...
  • Page 13 INSTALLATION The Door Answer Module with front cover Jetached showing the two screw terminals. Door Answer Unit The Door Answer Unit (DAU) is mounted on the backboard with the screws supplied. The Door Answer Unit is connected with a modular 6 conductor cord sup- plied with the Unit.
  • Page 14: Power Failure Transfer Option

    INSTALLATION Power Failure Transfer Option To provide Telephone service in the event of a com- merical power outage, a Power Failure Transfer Unit (PFT) must be installed. The PFT will allow all 3 of the TalkTo 308 system’s C.O./PABX lines to be transferred to 3 individual industry standard 2 wire telephones when the commer- cial power fails.
  • Page 15: System Programming

    INSTALLATION Cable Supplied with Power Fail Unit P F U Plug c o 3 co 1.2 RJ 4 Wire Modular Line Cord P l u g 308 KSU Used C N J Maximum 1 TK 3.4 Per incoming Line C.O.IPAB; Lines TK 1.2 co 3.4 T I T...
  • Page 16 SYSTEM PROGRAMMING System Requirements for Programming (7) Outgoing Call Restriction By Stu:ion: Allows indi- vidual stations to be restricted for toll and outgoing calls. For the system to be programmed to meet your re- There are three classes of service: A, B or C. quirements, it is necessary to decide what features are Class A: No restriction.
  • Page 17 SYSTEM PROGRAMMING Customer Feature Selection *Select ok item per Line Hold Recall (l)* 1 min IJ L min 0 3 min 0 No Recall Cl Tone Duration (2)* 55ms a 75ms 0 Flash/Cancel (3) * Flash 0 250 ms 0 500ms 0 1 set 0 3 set 0 Cancel GT 500ms is recommended for calibrated flash Pause on Number (4)
  • Page 18: Preparation

    SYSTEM PROGRAMMING Preparation ? Press the Reset key. Status Indicator lamp stops flashing. Before attempting to program the system, check Set the switch, Program 7 to Off. Station 10 is connected. Press the Reset key. The switches, Program 7 and 2, are set of Off. Press * key on station 10.
  • Page 19: Individual Feature Programming

    INDIVIDUAL FEATURE PROGRAMMING Features need not necessarily be programmed in Caiibrated Flash/Cancel a specific order. Each is accessed simply by entering the Access Code 030 specific 3-digit access code. The following charts show the Default is - 250ms Feature, the Access Code the Access Keys and their functions.
  • Page 20: Outgoing Call Restriction - B Y Station

    INDIVIDUAL FEATURE PROGRAMMING Outgoing Call Resiric tion, Night I =eature Data C.O. 1 C.O. 2 C.O. 3 hold Transfer and Private Lines - By Station mic. on/off Access Code 1Xx C.O. 1 N o ranging XX is station number 10-17) (where C.O.
  • Page 21 INDIVIDUAL FEATURE PROGRAMMING For each subsequent number to be programmed, press New numbers can be entered at anytime. Simply the speed key, dial the two digit access code, followed press the speed key, dial the two digit access code, enter by the speed call number to be programmed.
  • Page 22: Troubleshooting

    TROUBLESHOOTING Troubleshooting The purpose of this section is to assist maintenance personnel in locating and clearing faults in the Talk70 308 System. The system is composed of the following major components: TalkTo 308 Sets Door Answering Option Power Fail Option Communications cabling C.O./PABX lines PROVIDE...
  • Page 23 TROUBLESHOOTING REPORTED INOPERATIVE TROUBLE REPAlR DEFECTIVE STATION WIRING “ES GO TO TROUBLE SYSTEM CHECK NOTE RETURN DEFECTIVE “NITS FOR REPAlR Station Check...
  • Page 24 TROUBLESHOOTING ACCESS C 0 /PAM LINES CORRECT WIRING A N D R E C O N N E C T K S U TROUBLE (Yk-) C.O./PABX Line Access Chmk...
  • Page 25 TROUBLESHOOTING DOOR MODULE TROUBLE C H E C K WIRING DOOR ANSWER “NIT DOOR MODULE NOTE RETURN ANY DEFEdTlVE UNITS FOR REPAIR Door Answering - One Door Module...
  • Page 26 TROUBLESHOOTING DOOR ANSWERING OPERATIVE NOTE RETURN ANY DEFECTIVE “NITS FOR REPNR Door Answering - Two Door Modules...
  • Page 28 SYSTEM PROGRAMMING System Requirements -for Programming (7) Outgoing Call Restriction By Statian: Allows indi- vidual stations to be restricted for toll and outgoing calls. For the system to be programmed to meet your re- There are three classes of service: A, B or C. quirements, it is necessary to decide what features are Class A: No restriction.
  • Page 29 Night Transfer (8) Yes 0 Private Lines (9) W/Line No n Flexible Ringing (10) %/Line TRILLIUM t e l e p h o n e s y s t e m s Should you require service, please calf the following number:...

Table of Contents