Introduction Congratulations on the purchase of the CleanZone high-performance air filtration system. This system will provide you with many years of exceptional air cleaning performance. For your safety please study this manual carefully. Knowing about the CleanZone’s functions and features will also enable you to achieve the best results with the system. Keep this manual for future reference.
Summary of Key Features State-of-the-art filtration technology Your CleanZone H13 air filtration system utilises advanced air filtration technology to remove solid and liquid contaminants such as dust, aerosols, bacteria, viruses and smoke particles. The CleanZone H13 features the following air filtration technologies: •...
Chapter 1 Assembling the CleanZone Unpacking the CleanZone Your CleanZone is supplied in 2 boxes. The smaller box contains the air filtration system with its accessories and the larger box contains the acrylic hood. To unpack your CleanZone, remove the small box containing the power cord and the control panel.
Chapter 1 - Assembling the CleanZone Selecting the Required Setup IMPORTANT NOTE: The CleanZone H13 is a dual-function filtration system and can be used in two different ways. Carefully select the appropriate function for your application. Fitting the System the wrong way may result in pollution exposure.
Chapter 1 - Assembling the CleanZone Securing the CleanZone to the Hood IMPORTANT NOTE: Carefully select which way around the CleanZone is to be used for your application purposes. Fitting the system the wrong way may result in pollution exposure. Once the appropriate setup has been selected, the CleanZone can be fitted to the acrylic hood.
Chapter 1 - Assembling your CleanZone Fitting the Control Panel Once the CleanZone has been secured to the hood, the control panel can be fitted. 1) Take the flat-band cable on the front of the 2) Ensure that the curved edge of the panel system and slide it trough the gap of the housing faces down.
Chapter 2 Using the Control Panel Your CleanZone is operated and controlled via the electronic control panel which is located on top of the front locking arm. The electronic control panel allows you to: - control the fan speed and corresponding air delivery rate - check the remaining filter life of the individual filters - set the daily, weekly and countdown timers - reset the filter life counter after replacing a filter...
Page 10
Chapter 2 - Using the Control Panel Power Key The Power key turns your system on and off. When your CleanZone is turned off, the fan stops to run, but the system will remain connected to the power supply (standby mode). The standby mode allows for automatic timer start-up.
Chapter 2 - Using the Control Panel Fan Speed and Air Delivery Your CleanZone can be set to run at five fan speeds which correspond to five different air flow rates. Speed 1 is the lowest, speed 5 the highest fan speed.The higher the air flow, the more room air will be filtered by the unit.
Chapter 2 - Using the Control Panel Using the Menu Functions Your CleanZone’s control panel lets you choose from a number of menu options which allow you to take advantage of the additional features.There are eight menu windows that can be accessed with the Menu key.
Page 13
Chapter 2 - Using the Control Panel 6. Filter Life Menu Allows you to view the remaining filter life of the individual filter elements. 7. New Filter Menu Allows you to reset the remaining filter life after changing a filter element. 8.
Chapter 2 - Using the Control Panel Programming the Timer Functions Daily Timer Menu The Daily Timer Menu allows you to set one start and one stop time at which the system will automatically switch itself on and off.The CleanZone will start up in the fan speed it was in, when it was last used.
Page 15
Chapter 2 - Using the Control Panel 9. Enter the desired stop hour by pressing the ▲ key. 10. Press the Enter key to save the stop hour and to proceed to the minute setting. 11. Enter the desired minute setting by pressing the ▲...
Chapter 2 - Using the Control Panel Timer Information in the Control Panel The CleanZone’s control panel keeps you informed about the timer status without the need to use the Daily & Weekly Timer Menus. When the timer is enabled, the second line of the display’s main window shows the timer’s current start and the stop times.
Page 17
Chapter 2 - Using the Control Panel Countdown Timer Menu The Countdown Timer Menu allows you to set a period from 1 to 72 hours for which the CleanZone will run and then switch off automatically. Note: Should the daily timer also be enabled, the countdown timer will take priority until the countdown period has elapsed.
Chapter 2 - Using the Control Panel Chapter 2 Understanding the Control Panel 2. 5 Programming the Filter Load Index The filter load indexes serve as information input to the filter life monitor about the room air pollution and the resulting pollution load on the unit’s different filter elements. The filter load indexes are used by the filter life monitor for a more accurate calculation of the remaining filter life.
Page 19
Chapter 2 - Using the Control Panel Dusty Environments Environments with a high dust content may shorten the life of the pre-filter. If there is a frequently high dust content in your environment, add the following values to your index setting: Dust Presence Large Dust Index Fine Dust Index Above average...
Page 20
Chapter 2 - Using the Control Panel Modifying the Filter Load Indexes The Filter Load Index Menu lets you adjust indexes to reflect more closely the situation in your particular application environment. 1. Press the Menu key five times to reach the Filter Load Index Menu.
Chapter 2 - Using the Control Panel The Filter Life Menu Your CleanZone is equipped with an electronic filter life monitor that calculates the remaining life of the system’s filter elements. Thanks to the filter life monitor, you do not have to guess when filters need to be replaced or replace them at fixed intervals (which seldomly correspond to the actual amount of use).
Chapter 2 - Using the Control Panel Resetting the Filter Life LED The New Filter Menu allows you to reset the filter life counter for a newly replaced filter element. As a result, the appropriate filter life LED on the control panel will be reset to green and the hour count in the Filter Life Menu will be reset to the full life span of the new filter element.
Chapter 2 - Using the Control Panel The Display Language Menu The Display Language Menu allows you to change the CleanZone’s display language. The languages from which you can choose will depend on your CleanZone model and the country of purchase.
Chapter 3 Replacing Filters CAUTION! Do not change filters without taking proper safety precautions. When replacing filters after the filtration of potentially hazardous particles, the appropriate protective gear must be worn (e.g. respiratory protection, protective goggles, gloves). If the filters have been exposed to potentially hazardous particles, the filters may be classified as hazardous waste.
Chapter 3 - Replacing Filters Ordering Replacement Filters Please order your replacement filter elements by quoting the appropriate article numbers stated below: CleanZone H13 Pre-Filter F8 (S) Order No. 102 10 10 00 HEPA filter H13 (L) Order No. 102 16 13 00 Replacing the Pre-Filter 1) Disconnect the system from power.
Page 26
Chapter 3 - Replacing Filters 5) Turn the filter holder around and remove 6) Turn the filter holder around and carefully the filter clips which hold the pre-filter in press down on the filter element with the place. palm of your hand. 7) Lift the filter holder off the filter.
Chapter 3 - Replacing Filters Replacing the HEPA Filter 1) Disconnect the system from power. 2) Unscrew the wing screws and remove the CleanZone system from the hood. 3) Ensure that the filter you need to replace is 4) Remove the grill and lift out the top filter located in the top section of the system.
Page 28
Chapter 3 - Replacing Filters 7) Turn the filter holder around. 8) Place the new HEPA filter into the holder. Ensure that the arrows on the filter’s label point up. 9) Gently but firmly press the HEPA filter 10) Place the filter holder on top of the down into the filter holder with the palm of system and replace the grill.
Chapter 4 Caring for Your CleanZone Cleaning the Housing and Hood Unplug the system before attempting to clean it. Use a soft and clean cloth for cleaning. For water soluable stains, use a window cleaning fluid. For the removal of tough, non water soluble stains, use a silicon spray. Do not use any solvents or any organic cleaning fluids.
Chapter 5 Important Information & Technical Specifications Using the CleanZone in Critical Environments The following guidelines relate to the use of air-cleaning devices for airborne infection and contamination control purposes in health-care, research and production environments. These guidelines must be followed whenever CleanZone systems are used for the filtration of potentially harmful substances.
Chapter 5 - Important Information & Technical Specifications Technical Specifications: CleanZone ™ General Number of selectable fan speeds 1: 60 m /h 2: 110 m /h 3: 160 m /h 4: 240 m /h 5: 380 m Air delivery (with new filters) per speed ≥...
Chapter 5 - Important Information & Technical Specifications EU/UE KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY DÉCLARATION DE CONFORMITÉ INCEN AG Nous (Name des Anbieters) (supplier’s name) (nom du fournisseur) Blumenfeldstrasse 15 CH-9403 Goldach (Anschrift) (address) (adressse) erklären in alleiniger Verantwortung, dass das Produkt declare under our sole responsibility that the product déclarons sous notre seule responsabilité...
Chapter 6 Warranty & Service Information Technical Support Should technical problems arise during or after the warranty period, please contact your point of purchase or the manufacturer at: INCEN AG Phone: +41 71 844 0 844 Customer Service Fax: +41 71 844 0 845 Blumenfeldstr.
Warranty Conditions We are proud to cover this air cleaning system with a two (2) year limited warranty. If within 2 years from the original purchase date by the end-user from the authorised dealer this air cleaning system or any part thereof (with the exception of filters) is proved to be defective by reason only of faulty workmanship or materials, the manufacturer will at their option repair or replace the faulty system or part free of charge for labour and materials.
Need help?
Do you have a question about the CleanZone H13 and is the answer not in the manual?
Questions and answers