Wheelock SAFEPATH SP-COA Installation Instructions

C.o. port adapter

Advertisement

Quick Links

273 Branchport Avenue
Long Branch, NJ 07740
(800) 631-2148
www.wheelockinc.com
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
GENERAL:
®
Wheelock's SAFEPATH
Telephone (TEL) input.
The unit is attractively packaged for wall mounting. The SP-COA requires connection to a 24VDC filtered and regulated power
supply, which supplies power to the unit and talk battery for the unused C.O. Port. Two wires are connected from the unused C.O.
Port to the telephone input (TEL INPUT) terminals on the SP-COA. The telephone output (TEL OUTPUT) is then connected to the
telephone input (TEL) connections on the SP40/2 motherboard. See Figure 2.
NOTE: All CAUTIONS and WARNINGS are identified by the symbol
WARNING: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. FAILURE
TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN
IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY
SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU
AND/OR OTHERS.
INSTALLATION INFORMATION:
WARNING: DO NOT CONNECT AC POWER OR BATTERY BACKUP POWER UNTIL SYSTEM WIRING HAS
BEEN CONNECTED OR THE SP-COA HAS BEEN MOUNTED, AND FIELD WIRING HAS BEEN INSPECTED.
Connect the SP-COA TEL INPUT to the unused C.O. Port or a stand-alone telephone. Connect the SP-COA TEL OUTPUT to the
TEL terminals on TB5 on the SP40/2. Connect the SP-COA POWER terminals to a 24VDC filtered and regulated power supply
(Wheelock's part number RPS-2406 is recommended). See Figure 1 for details.
UNUSED CO
PORT OR
STAND ALONE
TELEPHONE
Copyright 2002 Wheelock, Inc. All rights reserved.
Thank you for using our products.
INSTALLATION INSTRUCTIONS
SAFEPATH
4 C.O. Port Adapter (SP-COA) is used when connecting between an unused C.O. Port and the SP40/2
+
-
®
4 C.O. Port Adapter
SP-COA
. All warnings are printed in bold capital letters.
Figure 1:
-
+
RPS-2406
+
24V INPUT
-
+
TEL
+
-
OUTPUT
-
TEL
INPUT
SP-COA
SP40/2
+
TEL
-
INPUT
P84341 A
Sheet 1 of 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the SAFEPATH SP-COA and is the answer not in the manual?

Questions and answers

Summary of Contents for Wheelock SAFEPATH SP-COA

  • Page 1 Connect the SP-COA TEL INPUT to the unused C.O. Port or a stand-alone telephone. Connect the SP-COA TEL OUTPUT to the TEL terminals on TB5 on the SP40/2. Connect the SP-COA POWER terminals to a 24VDC filtered and regulated power supply (Wheelock’s part number RPS-2406 is recommended). See Figure 1 for details. Figure 1:...
  • Page 2 MOUNTING INFORMATION: Hang the C.O. Port Adapter vertically on the two mounting screws supplied. Space the screws vertically on 2" centers per Figure 3. Connect all wiring as per Figure 1. The SP-COA terminals accept #16 through #24 AWG. Strip insulation to expose 3/8" of bare wire.
  • Page 3 TROUBLE SHOOTING GUIDE: Condition Check 1) SP-COA cannot be accessed Check presence and polarity of voltage on + & - 24 VDC terminals and that power is filtered and regulated. Verify SP-COA has released from last page. Check the SP40/2 is not in a trouble condition. Verify that “Tel Input”...
  • Page 4: Limited Warranty

    IN NO EVENT SHALL WHEELOCK BE LIABLE FOR ANY CLAIM OF ANY KIND UNLESS IT IS PROVEN THAT OUR PRODUCT WAS A DIRECT CAUSE OF SUCH CLAIM. FURTHER, IN NO EVENT, INCLUDING IN THE CASE OF A CLAIM OF NEGLIGENCE, SHALL WHEELOCK BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.