This document shows how to install an EP-80R temp sensor and how to
connect it to a NMEA 2000
how to configure your temp sensor with Lowrance digital gauges (LMF-
200 & LMF-400) and display units.
NMEA 2000 is the communication bus standard developed by the
National Marine Electronics Association (NMEA) for use in boats.
Lowrance has introduced a line of products that can communicate over
a NMEA 2000 network (LowranceNet).
All Lowrance NMEA 2000 capable devices are either NMEA 2000
certified or certification is pending.
CAUTION:
Installing LowranceNET NMEA 2000 devices is significantly
different from installing earlier Lowrance components without
NMEA 2000 features. You should read all of the installation
instructions before proceeding. Decide where you want to install
all components before drilling any holes in your vessel.
Some sonar or GPS display units may require a software upgrade to
display NMEA 2000 data correctly. For free software upgrades or
additional information on the LowranceNet NMEA 2000
system, visit our web site, www.lowrance.com.
Temp
module
EP-80R Temp
®
network. It also provides instructions on
The EP-80R temperature sensor.
Smart module
1
Pub. 988-0154-472
®
network
NMEA 2000 red
cable connector

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EP-80R Temp and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lowrance EP-80R Temp

  • Page 1 Pub. 988-0154-472 EP-80R Temp Electronic Temperature Sensor Installation and Configuration Instructions This document shows how to install an EP-80R temp sensor and how to ® connect it to a NMEA 2000 network. It also provides instructions on how to configure your temp sensor with Lowrance digital gauges (LMF- 200 &...
  • Page 2 NMEA 2000 data format. The cable length measures 18 inches (46 cm) from the connector to the smart module and 10 feet (3 meters) from the smart module to the temp module. The EP-80R Temp, like the other LowranceNet Electronic Probe (EP) sensors, is designed for use with a NMEA 2000 network.
  • Page 3: Installation

    LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot extension cable, T connector and two 120-ohm terminators. Installation The EP-80R temperature sensor can be mounted in any location where you want temperature to be monitored. The most common applications are transom mounts —...
  • Page 4: Network Backbone And Network Nodes

    A NMEA 2000 network is a communications link between two or more devices that transfer NMEA 2000 information. LowranceNET is the NMEA 2000 networking system developed by Lowrance Electronics. A NMEA 2000 network functions like the phone wiring in a house. If, for example, you pick up a phone in the living room you will be able to hear the conversation someone is having on a phone in the bedroom.
  • Page 5: Adding A Network Node

    T connectors may be purchased from LEI (ordering information appears on the back page of this booklet). If you are adding a Lowrance or LEI NMEA 2000 sensor, it will come with a T connector. Adding a Network Node You can add a node to any existing connection, anywhere along the network backbone.
  • Page 6: Additional Network Information

    If you want to add a node at the end of the backbone (network bus) remove the terminator from the last connector, like the figure above. Install the new T connector and attach the terminator to the side of the connector.
  • Page 7: Boat Setup

    Boat Setup before you will be able to configure your temp sensor. If you have already completed Boat Setup skip ahead to the segment covering EP-80R Temp Configuration. To execute Boat Setup: 1. With Boat Setup highlighted on the screen, press .
  • Page 8 . The Setup screen will appear with Boat Setup MENU highlighted. EP-80R Temp Configuration The EP-80R Temperature sensor has three configuration options: Inside, Outside and Water. An unconfigured temperature sensor will appear on the Bus Devices list as UnCfg Temp.
  • Page 9 To unconfigure a temp sensor: 1. Press , use the keys to select MENU DOWN YSTEM ETUP press MENU 2. Highlight and press , which will open the Bus Devices B. D MENU EVICES list. 3. Select a temp sensor from the Bus Devices list and press .
  • Page 10 If your temp sensor is not updated on the Bus Devices list, refresh the list by letting it time out and then access it again. Displaying EP-80R Temp Sensor Data You can display your temperature sensor data on the Gauge, Single Digital and Dual Digital pages.
  • Page 11 pages to automatically scroll across the screen. Refer to your LMF -200 manual for information about Autoscroll. Adding a page: 1. Press , use the keys to select and press MENU DOWN AGES , which will open the Pages menu with the following options: Add MENU Page, Rem Page, Autoscroll and Set Pop-up.
  • Page 12 3. Select the desired data position and press MENU 4. Highlight and press . The Select Temp menu will appear MENU with three temp types: Inside, Water and Outside. 5. Select the desired type and press . You will be taken back to MENU the main display.
  • Page 13 Boat Setup before you will be able to configure your temp sensor. If you have already completed Boat Setup, skip ahead to the segment covering EP-80R Temp Configuration. To execute Boat Setup: 1. The Boat Setup menu will appear, allowing you to select an engine- tank configuration to match the number of engines and fuel tanks on your vessel.
  • Page 14 . The Setup Menu will appear with Boat Setup MENU highlighted. EP-80R Temp Configuration The EP-80R Temperature sensor has three configuration options: Inside, Outisde and Water. An unconfigured temperature sensor will appear on the bus devices list as UnCfg Temp.
  • Page 15 3. Choose the desired temp sensor and press . Select ENTER NCONFIGURE from the temp configuration menu and press . The following ENTER message will appear: Press Menu to UnConfig Device Name. 4. Press to unconfigure the sensor. You will be directed to the ENTER Bus Devices list where the temp now will be listed as UnCfg Temp.
  • Page 16 If your temp sensor is not updated on the Bus Devices list, refresh the list by closing it and then access it again. Displaying EP-80R Temp Sensor data: You can display temp sensor data on the Single Analog, Dual Analog, Quad Analog, Single Digital, Dual Digital and Quad Digital pages.
  • Page 17 To add a page to the display: 1. Press , use the keys to select and press MENU DOWN AGES . A menu will pop up with four options: Add Page, Remove Page, ENTER Page Scrolling and Pop-Ups Setup. Select and press ENTER 3.
  • Page 18 5. Highlight and press . The Select Temp menu will ENTER EMPERATURE appear with three temp types: Water Temp, Outside Temp and Inside Temp. 6. Select the desired temp type and press . You will be directed to ENTER the Position menu. Repeat steps 4 and 5 to customize the other position, or press twice to return to the main display.
  • Page 19 4. Select and press . The Select Temp menu will ENTER EMPERATURE appear with three temp types: Water Temp, Outside Temp and Inside Temp. 5. Select the desired temp type and press . You will be directed to ENTER the Position menu. Repeat steps 3 through 5 to customize the other position, or press twice to return to the main display.
  • Page 20 Notes...
  • Page 21: Bus Setup

    This section will show you use a NMEA 2000 compatible display unit with your EP-80R Temperature Sensor. The LMS-525cDF is one of many Lowrance display units that may be used to configure an EP-80R Temperature sensor. NMEA 2000 Menu/Networking Menu Your unit may have a NMEA 2000 menu or a Networking menu, depending on the software version installed in your unit.
  • Page 22 Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup selected on Networking menu (right). EP-80R Temp Sensor Configuration The Temp Type function will be used when configuring your temp sensor through a display unit. You will select a configuration name for the temp from the Temp Type menu.
  • Page 23 4. Press . Use the arrow keys to input the desired name for the ENTER temp sensor and press . Press repeatedly to return to the ENTER EXIT main display. To reset device name to default setting: 1. Press twice, select and press MENU NMEA 2000...
  • Page 24 Unconfiguring a Temp Sensor You could unconfigure a temp sensor by changing its temp type to unknown or you can use the Restore Defaults command, which will reset the temp type and device name to default settings. To restore default settings 1.
  • Page 25 ENTER EXIT the main display. Displaying EP-80R Temp Sensor Information The Overlay Data function will be used to show temp sensor data on your unit's main display. To add temp sensor as overlay data: 1. Press...
  • Page 26 Notes...
  • Page 27 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRANCE ELECTRONICS, INC., the manufacturer of this product. "You" or "your" refers to the first person who purchases this product as a consumer item for personal, family or household use.
  • Page 28: Accessory Ordering Information

    For Eagle: 8 a.m. to 5 p.m. Central Standard Time, M-F Lowrance Electronics and Eagle Electronics may find it necessary to change or end their shipping policies, regulations and special offers at any time. They reserve the right to do so without notice.

Table of Contents