Troubleshooting; Specifications - Schumacher Charge 'n Ride CR1 Owner's Manual

Automatic battery charger
Table of Contents

Advertisement

Available languages

Available languages

NOTE: For longer battery life, the battery must be completely charged after two
consecutive quick charges. (Example: quick-quick-complete.)
Aborted Charge
If charging can not be completed normally, charging will abort. When charging aborts,
the charger's output is shut off, and the CHARGING
aborted charge, unplug the charger from the AC outlet, wait a few moments and plug it
back in.
8.
MAINTENANCE/STORAGE INSTRUCTIONS
8.1 After use and before performing maintenance, unplug and disconnect the battery charger.
8.2 Use a dry cloth to wipe all battery corrosion and other dirt or oil from the connector, cords
and the charger case.
8.3 Servicing does not require opening the unit, as there are no user-serviceable parts.
Servicing should be performed only by qualified service personnel.
8.4 Store the charger unplugged, inside, in a cool, dry place.
9.

TROUBLESHOOTING

PROBLEM
Power light will not
turn on.
CHARGING
flashing.
CHARGED
LED is
flashing.
10. BEFORE RETURNING FOR REPAIRS
10.1 When a charging problem arises, make certain that the battery is capable of accepting a
normal charge. Double check all connections, the AC outlet for a full 120 volts and the quality
of the connections from the connector to the battery system. The connector must be clean.
10.2 When an UNKNOWN OPERATING PROBLEM arises, please read the complete manual and
call the customer service number for information. This will usually eliminate the need for return.
If the above solutions do not eliminate the problem, or for more information
about troubleshooting, call toll-free from anywhere in the U.S.A.
7:00 a.m. to 5:00 p.m. Central Time, Monday through Friday
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.

11. SPECIFICATIONS

Input Voltage ........................................................................................................... 120 VAC
Output Current Rating .......................................................................................... 12V – 3.0A
...............................................................................................................................
Maximum Charge Voltage ..................................................................................12V – 15.4V
...............................................................................................................................6V – 7.7V
Maintain Voltage .................................................................................................12V – 13.6V
...............................................................................................................................6V – 6.8V
Size ........................................................................................................2⅝" H x 6" W x 3" D
Weight ......................................................................................................................... 2½ lbs
POSSIBLE CAUSE
AC outlet is dead.
Poor electrical connection.
Charger is in abort mode.
LED is
Battery is 80% charged and is
ready to use.
1-800-621-5485
5
LED will blink. To reset after an
REASON/SOLUTION
Check for an open fuse or circuit
breaker supplying the AC outlet.
Check the power cord
and extension cord for a loose
fitting plug.
See Section 7 OPERATING
INSTRUCTIONS – Aborted
Charge.
See Section 7 OPERATING
INSTRUCTIONS – Quick Charge.
6V – 3.0A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents