4. The case temperature becomes hot (exceeds 145°F). The
Green and Red LEDs are on, with a buzzer. Solution: Allow
the converter to cool. Do not block the cooling slots or air
flow over and through the converter. Reduce the load on the
converter to the continuous rated output.
RESET: To reset after shutdown occurs:
1. Disconnect the converter from the 12V power source.
2. Check the source of the problem and correct.
3. Reconnect the converter to the 12V power source.
NOTE: If the red LED is lit and the green LED is not, see the
Troubleshooting section.
8.

IF THE CONVERTER FUSE BLOWS

Your power converter is fitted with a fuse, which should not have
to be replaced under normal operating conditions. A blown fuse
is usually caused by reverse polarity or a short circuit within the
device or equipment being operated.
If the fuse does blow:
1. Disconnect the device or equipment immediately.
2. Find the source of the problem and repair it.
3. Install a new fuse (25A). The fuse can be found on the back of
the converter.
the original fuse, as this may damage the converter and any
product you use with the converter. Make sure to correct the
cause of the blown fuse before using the converter again.
Do not install a fuse with a higher amp rating than
• 9 •