Selecting Menu Presets; Reviewing Operating Setpoints; Alarm; Calculating The Water Temperature - Garland PHD PLUS Installation And Operation Manual

Product holding drawer
Table of Contents

Advertisement

OPERATING INSTRUCTIONS Continued

Selecting Menu Presets

When menu presets have been programmed they are then
available in operation mode. To select a preset, press the
select key momentarily. The first preset "P_" will appear. Press
the Select key momentarily again to select another menu
preset or continue to press the Select key momentarily to
scroll through the menu presets.

Reviewing Operating Setpoints

In operation mode, press the
temperature set point. Press the
set point

Alarm

If air temperature is < (less than the (Air setpoint – 10°C or
18°F) or > (greater than) the (Air setpoint + 10°C or 18°F), the
air temperature display will flash. Pressing any key will stop
the display from flashing.
-15
-10
Page 10
key to view the air
key to view the humidity
Humidity Relationship Versus (Air set point – Water set point)
110
100
90
80
70
60
50
40
30
-5
0
5
Air Set point temperature – Water Set point temperature in Fahrenheit

Calculating the Water Temperature

To provide a simple and consistent means of setting the
chamber humidity we have created a relationship between
the water temperature and the air temperature where the
lower heat source is scaled in percent relative humidity.
By setting the humidity to minimum (10%), the lower
temperature will match the air temperature. In applications
where it is necessary to set the lower element temperature
less than the air temperature in dry mode or for a reference is
humidity mode we provide the preceding chart to calculate
the set point.
Humidity relationship for humidity
higher than 58% rh
Humidity relationship for a
humidity lower than 58% rh
10
15
20
25
30
35
Part # 1844066 Rev 01 (02/13/2008)
110
100
90
80
70
60
50
40
30
40