Download Print this page

La Crosse Technology EA-3010 Operating Manual page 2

Hand held anemometer
Hide thumbs Also See for EA-3010:

Advertisement

Measurement scale setting
1.
After entering the manual setting mode, press "+" key to set the
measurement scale in Km/h (Kilometers per hour), mph (miles
per hour), m/s (meters per seconds) or Kts (Knots).
2.
Now press the "MODE/ " key to confirm and enter the "°C and
°F setting".
°C and °F setting:
1.
Following from the measurement scale Setting °C will be
flashing, use the "+" key to toggle °C and °F.
2.
Once the desired temperature unit has been chosen, press the
"MODE/ " key to confirm and enter the "Average time for
current speed measurement setting".
Average time for current speed measurement setting
The current wind speed can be measured in average wind speed in a
time interval of 2-10 seconds
1.
Following from the °C and °F Setting, press "+" key to set the
desired average time. The range runs from 2 to 10 seconds.
2.
Once the desired average time has been chosen, press the
"MODE/ " key to confirm and back to the normal mode.
LCD backlight:
The LCD backlight is automatically switched ON when any one of the
2 function keys are pressed and held down for 2 seconds. The
backlight will be switched on for approximately 8 seconds before
automatically switching OFF.
Battery change:
It is recommended to replace the battery in the unit on an annual
basis to ensure optimum accuracy of this unit.
Please help in the preservation of the environment.
Return used batteries to an authorized depot.
Maintenance:
• Avoid placing anemometer in areas prone to vibration and shock
as these may damage and inaccurate readings.
• Avoid exposure to sudden changes in temperature such as direct
sunlight, extreme cold and wet or moist conditions.
• When cleaning the display and casing, use a soft damp cloth only.
Do not use solvents or souring agents as they may mark the LCD
and casing.
• Do not make or attempts to make any repairs to the anemometer.
Return it to its original point of purchase for repair by a qualified
engineer. Opening and tampering with the unit may invalidate its
warranty.
Specifications:
Recommended operating temperatures : -21.8 °F to 138.2 °F with 0.2°
Temperature checking interval
Wind speed measuring range
Power source
Battery life
Dimensions (L x W x H)
Liability Disclaimer:
The manufacturer and supplier cannot accept any responsibility
for any incorrect readings and any consequences that occur
should an inaccurate reading take place.
This product is not to be used for medical purposes or for public
information.
The specifications of this product may change without prior
notice.
This product is not a toy. Keep out of the reach of children.
No part of this manual may be reproduced without written
consent of the manufacturer.
resolution
(-29.9°C to +59°C with 0.1°C
resolution)
("---" displayed if outside this range)
: every 10 seconds
: Minimum 0.4 mph (0.2 m/s)
Maximum 67 mph (30 m/s)
: 1 x 3V lithium cell (CR2032)
: Approximately 12 months
: 1.5" x 0.6" x 3.8" (39 x 17 x 98 mm)
WARRANTY INFORMATION
La Crosse Technology provides a 1-year warranty on this
anemometer. Contact La Crosse Technology immediately upon
discovery of any defects covered by this warranty.
Before sending the anemometer in for repairs, contact La Crosse
Technology. The anemometer will be repaired or replaced with the
same or similar model during the warranty period.
This warranty does not cover any defects resulting from improper
use, unauthorized repairs or faulty batteries.
LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR
DAMAGES ASSOCIATED WITH THE OPERATION OR
MALFUNCTION OF THIS ANEMOMETER. THIS PRODUCT IS NOT
TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC
INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF
CHILDRENS' REACH.
This warranty gives you specific legal rights. You may also have
other rights specific to your State. Some States do no allow the
exclusion of consequential or incidental damages therefore the above
exclusion of limitation may not apply to you.
For warranty work, technical support, or information contact:
La Crosse Technology
2809 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
support@lacrossetechnology.com
(warranty work)
sales@lacrossetechnology.com
(information on other products)
www.lacrossetechnology.com
All rights reserved. This handbook must not be reproduced in any
form, even in excerpts, or duplicated or processed using electronic,
mechanical or chemical procedures without written permission of the
publisher.
This handbook may contain mistakes and printing errors. The
information in this handbook is regularly checked and corrections
made in the next issue. We accept no liability for technical mistakes
or printing errors, or their consequences.
All trademarks and patents are acknowledged.
e-mail:
web:

Advertisement

loading

Related Products for La Crosse Technology EA-3010

This manual is also suitable for:

Ea-3010twcEa-3010twc