INSTALLATION
In determining a suitable location for installation, it is important
to ensure you allow adequate access for servicing.
The following instructions are designed to assist engineers
in the safe and effective installation and servicing of the
SALUS Mag Defender and should be followed at all times.
Any queries arising from either installation or servicing, contact
SALUS Controls direct on 01226 323961.
Do's:
• Install the filler upright to enable the device to be fully
evacuated of air during commissioning. Pipe runs are vertical,
horizontal or any angle in between. The inlet and outlet can
also be swapped to suit.
• Where the device is fitted to the metallic building structure
earth-bonding continuity is required around the device.
All bonding connections must be accessible and labelled
"Safety Electrical Connection - Do Not Remove"
Dont's:
• Magnets may affect or interfere with sensitive mechanical and
electronic instruments such as heart pacemakers, computers/
magnetic media and watches. Always keep magnets at least
300mm (1ft) away from such equipment.
• NEVER close the INLET or OUTLET isolation valves, or UNDO the
lid when the pump is running!
• Don't fit the device too close to the boiler, allow at least 1m.
4
MD22 INSTRUCTION MANUAL