Temperature and Humidity Range

Outdoor temperature
Indoor temperature
● If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to
prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature
than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
● Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
● If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and
drip onto the fl oor or other objects underneath. (About 80% or more).
● If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the
outdoor unit may stop operation for certain period of time.

SPECIFICATION

TYPE
HEAT & COOL MODEL
INDOOR UNIT
MODEL
OUTDOOR UNIT
POWER
COOLING
CAPACITY
INPUT POWER
CURRENT
HEATING
CAPACITY
INPUT POWER
CURRENT
En-17
MODEL
Cooling Mode
18R
About 14 to 115 °F
24/30R
About 0 to 115 °F
18/24/30R
About 64 to 90 °F
ASU18RLXS
AOU18RLXS
208/230 V 60Hz
18000 Btu/h
1.38 kW
6.3 A
21600 Btu/h
1.80 kW
8.0 A
Dry Mode
About 14 to 115 °F
About 0 to 115 °F
About 64 to 90 °F
ASU24RLXS
AOU24RLXS
208/230 V 60Hz
22000 Btu/h
1.76 kW
7.9 A
27600 Btu/h
2.38 kW
10.5 A
Heating Mode
About 5 to 75 °F
About 0 to 75 °F
About 86 °F or less
ASU30RLX
AOU30RLX
208/230 V 60Hz
30000 Btu/h
3.00 kW
13.2 A
32000 Btu/h
2.99 kW
13.1 A