Download Print this page
Emerson ACM1600M-108 Owner's Manual
Emerson ACM1600M-108 Owner's Manual

Emerson ACM1600M-108 Owner's Manual

Media air cleaner with media filter

Advertisement

Quick Links

EMERSON_
Media
Air C|eaner
With
Media
Fi|ter
Model Number
ACM1000M-XXX
ACM1400M-XXX
ACM1600M-XXX
ACM2000M-XXX
OWNERS
MANUAL
• Installation
• Operation
• Maintenance
i
(_lease
read and familiarize
yourself with the contents
of this manual
beforeh
_nstalling,
operating
or performing
maintenance
on the unit.
J
EMERSON
White-Rodgers
is a division
of Emerson Electric Co.
www.white- rodge rs.com
PART NO. 37-7001A
0922

Advertisement

loading

Summary of Contents for Emerson ACM1600M-108

  • Page 1 • Operation • Maintenance (_lease read and familiarize yourself with the contents of this manual beforeh _nstalling, operating or performing maintenance on the unit. White-Rodgers is a division PART NO. 37-7001A of Emerson Electric Co. EMERSON www.white- rodge rs.com 0922...
  • Page 2 The Emerson Media Air Cleaner comes complete with a 4" GUARANTEE media furnace air filter. This filter must be changed every three Emerson will not assume any responsibility for component to six months to maintain efficiency of the filter and furnace failures due to incorrect installation procedures.
  • Page 3 HOWTHE AiR FILTER WORKS Dirty air flows through your return air ducts and enters the compartment where particles (hair, lint, etc.) are removed by 4" FILTER the filter. See figure 1. Filtered air re-enters to the supply duct system of your o_ooooooee building.
  • Page 4: Pre-Installation

    PREINSTALLATION LOCATING THE AiR FILTER 3. The air filter is not to be placed in the discharge of either the heating or cooling unit. Your air filter must be mounted in the return air duct of a central 4. IMPORTANT: If atomizing spray type humidifier is used, it forced-air system, on the air entering side of your furnace.
  • Page 5: Mounting Positions

    TYPICAL MOUNTING POSiTiONS AIR FLOW AIR FLOW <2> Figure 5 Figure 6 BASEMENT FURNACE (LOWBOY) COUNTERFLOW FURNACE Filter is mounted horizontally in return plenum, just above Filter is mounted horizontally furnace. in return duct or plenum, just above furnace. AIR FLOW Figure 7 Figure 8 HIGHBOY FURNACE...
  • Page 6: Installation

    INSTALLATION REMOVE OLD FILTER AND DISCARD (Figure 11) NOTE: This filter may be mounted in the furnace compartment. CLEAN BLOWER COMPARTMENT NOTE: The air filter cannot remove dirt from blower and ducts. Figure 11 iNSTALLATiON The following is a typical installation of the air filter on a "Highboy"...
  • Page 7 NOTES...
  • Page 8 Whiter White-Rodgers is a division Rodgers,M of Emerson Electric Co..The Emerson logo is a EMERSON trademark and service mark www.white=rodgers.corn of Emerson Electric Co.