If the cooktop detects an internal / external error or a wrong connection, it will display
the error message with a code number on the display panel and the cooktop will stop
functioning. These code numbers will allow you identify the cause of the error and
help you fi nd the solution to the problem. If the problem has been solved the error
message will disappear and you will be able to continue using your cooktop. If the
error persists, please call Fagor's customer service for assistance. You can reach us
at 1-800-207-0806
E3, E5, E9:
Solution:
E1:
Solution:
E2:
Solution:
E7:
Solution:
EE:
Solution:
DIBW Manual Rev'n.indd 15
DIBW Manual Rev'n.indd 15
Failure of an internal component or electric connection.
Do not attempt to repair the cooktop yourself. Please call our
customer service for instruction on how to send the unit back for
repair.
Electronic control of low voltage.
Make sure the cooktop is connected to the correct voltage.
Electronic control of high voltage.
Make sure the cooktop is connected to the correct voltage.
Overheating protection.
Make sure there is a minimum distance of 5 inches between the
ventilation slot (found at the back of the cooktop) and any obstruction
such as a wall or other appliances. Unplug and let the unit cool down.
Plug back in and press the ON/OFF button followed by the START
button.
Timer error.
This indicates an error with the programmable timer. Turn the unit off
and on again and try programming the timer again.