Download Print this page

Trane 4TTR2042A1000A Use And Care Manual page 33

1 1/2-5 tons

Advertisement

Performance
Data
Cooling
Q
71MNE
4TFR2030A1 _
TVF030A14 AT 1000 CFM
O.D,
I.D.
TOO
SENS. CAP.AT ENTERINGD.B,TEMP
TOTAL
D.B.
W.B,
CAP,
72
75
76
80
KW
59
26.9
240
26.9*
27.9'
29.6"
249
95
63
28.8
20.9
230
26.6
28,0
2,51
67
30.9
15.6
186
216
23,6
2.53
59
26.2
23.7
26.4"
274*
28,0"
2,76
95
63
28.2
19.7
227
25,7
27.7
2,78
67
30.2
15.3
18.3
213
23.4
2.91
63
26.0
19.0
22.9
250
26.6'
3.06
105
67
28.4
14.6
176
20.6
226
3.09
71
30.4
10.1
13.2
16,2
18.2
3.12
63
24.8
18.2
21.2
243
28.2"
3.33
115
67
26.7
13.9
16,9
19,9
21.9
3.36
71
28,6
9,4
12.6
155
17.5
3.40
CORRECTIONFACTORS- OTHERAIRFLOWS(MULTIPLYOR ADDAS INDICATED)
NRFLOW
875
1t25
AIRFLOW
875
1125
TOTALCAP
X0.98
X1.01
SENS. CAP
X0.94
X1 06
41"rR2030A1 WITH WF036A14 AT 1100 CFM
O,D.
I.D,
TOT
SENS,CAP. ATENTERINGD.B, TEMP
TOTAL
O,B.
W.B,
CAP,
72
75
76
60
KW
59
27.4
25,3
278"
28.8*
29.5'
2.59
85
63
29.4
20.8
24.2
27,6
29.5'
2,61
67
31.4
16.0
19.3
22,6
24.9
2,63
59
86.7
25.0
27,2'
283'
28.9'
2.87
98
63
28.7
20,5
23.9
272
29,9*
2,89
67
30.7
15.7
19.0
224
24.6
2.92
63
27.0
19,8
23.1
265
27,5*
3,16
105
67
28.9
15.0
18.3
21,6
23.9
3,20
71
31.0
19.0
13.4
16,7
19,0
9.23
63
25,3
19,1
22.4
25.4"
96,0*
3.43
115
67
27.1
!4.3
17,6
20.9
93.2
3.47
71
29.1
9.4
127
16.0
18.3
3.51
CORRECTION FACTORS- OTHERAIRFLOWS(MULTIPLYOR ADD AS INDICATED)
AIRFLOW
950
1250
AIRFLOW
950
1250
TOTALCAP
X0.88
X1.01
SENS CAP
X0.93
X1.06
4TrR203OA1 WITH TWE024C14 AT 900 CFM
O,D.
LD.
TOO
SENS. CAP,AT ENTERINGD.B.TEMP
TOTAL
D.R,
W,B.
CAP.
72
75
78
80
KW
58
24.4
20.6
22.9
24.7'
26.3"
2.38
85
63
26.3
17.5
19.9
29.2
23,8
2.40
67
28.3
14,1
16.5
18.8
20.3
2.42
59
23.9
20,3
22,6
24.3*
24.9"
2.64
95
63
25.8
17.3
19.6
22.0
23.5
2.66
67
27.8
13.9
16,2
18,6
20.1
2.58
63
24.3
16.6
18,9
21.3
22.8
2.94
105
67
26.2
13,2
15,6
17.9
19.5
2,97
71
282
9,8
12.1
144
16.0
3.00
63
22,8
15.9
18.3
20.6
22,1
3,21
115
67
24,6
12.6
14.9
17.2
18.6
3,25
71
26.5
9.1
11.5
13,8
15.3
3,28
CORRECllON FACTORS- OTHERAIRFLOWS (MULTIPLYOR ADDAS INDICATED)
AIRFLOW
775
1026
AIRFLOW
775
1025
TOTALCAP
X0.97
X1,02
SENS,CAP
X0.94
X! .05
4TTR2030A1 WITH TWE030C14 AT 900 CFM
0.0.
I.D.
TOT
SENS.CAP. ATENTERINGD,B.TEMP
TOTAL
O.B.
W.B.
CAP,
72
75
78
80
KW
59
25,5
21.9
24.1
259*
266*
240
95
63
274
19.3
908
234
250
2.42
67
295
14,6
17.1
197
214
2.44
59
24.9
91.3
23.9
254'
26.1'
266
95
63
268
18,0
205
23.1
24.8
2.69
67
28.8
143
16.6
19.4
21.!
2.71
63
25.2
17,3
19.8
22.3
24.0
2.96
105
67
271
13.6
192
197
20,4
2,99
71
99,0
9,9
12,4
14.9
t6.6
3.02
63
23.5
16.6
181
216
93.3
3,93
1!5
97
25.3
12.9
154
180
197
327
71
27.2
9.2
117
14.3
15,9
3,31
CORRECTION FACTORS- OTHERAIRFLOWS(MULTIPLY OR ADDAS INDICATED)
AIRFLOW
770
1025
AIRFLOW
775
1025
TOTALCAP
X0,98
X1,02
SENS CAP
X0.94
X1,06
4TI'R2030A1 WiTH 1_E036C14
AT 1100 CFM
O.D.
I.D.
TOT
SENS, CAP.AT ENTERINGD.B. TEMP
TOTAL
D.B.
W.B.
CAP.
72
75
78
80
KW
59
263
24,6
268*
278*
28.4*
2,52
85
63
28.3
20.4
235
26.7
28.4*
954
67
30,3
15.9
169
221
24.2
2.66
59
25.6
24.3
26.3*
27,3*
28,0"
2,79
95
53
27.7
20.1
23.3
26.4
26.0'
2.92
67
29.7
15.6
19.7
218
23,9
2.84
63
28.1
19,4
22.6
25.7
26.6"
3.09
105
67
29,1
14.9
19.0
21.1
23.2
3.12
71
30,1
10.2
13.4
16.5
18.6
3.15
63
24.5
18.7
21,9
247"
253"
936
115
67
26.4
14,2
17,3
20,5
22.5
3,40
71
28.3
9.6
127
15,8
17,9
3,44
CORRECTIONFACTORS- OTHERAIRFLOWS(MULTIPLYORADO AS INDICATED)
AIRFLOW
950
1250
AIRFLOW
950
1250
TOTALCAP
X098
X1.01
SENS,CAP
X0.94
X1.06
41TR2030A1 WITH TWE042C14 AT 1100 CFM
O.D.
I.D.
TOT
SENS.CAP, AT ENTERINGD.B.TEMP
TOTAL
O.B,
W.B.
CAP.
72
75
78
60
59
27.0
24,9
27.9*
28.4"
29.0"
255
85
63
29,9
20.6
23,8
27,0
29.0*
256
67
31,0
160
19,2
223
24.5
2.59
59
26.3
24.6
26.8*
97.8*
28.5*
2.82
95
63
28.3
20.4
23.5
26.7
28.5*
2.84
67
30.3
15.7
18.9
22.1
24.2
2.67
63
26.6
196
22.6
26.0
27.1"
3.11
105
67
28,6
15.0
18.2
21.4
23.0
3.15
71
30.6
10.3
13.5
16.7
18,8
3,18
63
25.0
18.9
22,1
25,1"
25,7"
3,38
115
67
26.9
14.3
17,5
20,7
22.8
3.42
71
28.0
9.6
126
16.0
18.1
3.46
CORRECTIONFACTORS- OTHERAIRFLOWS(MULTIPLY OR ADOAS INDICATED)
AIRFLOW
950
1250
AIRFLOW
950
1250
TOTAL CAP
X0,98
X101
SENS.CAP
X094
X1.06
NOTE:ALLTABLESABOVEAREATARI RATINGCONDITIONS RATED WiTH25 FEET OF REFRIGERANT LINES
• DRY COILCONDKION (TOTALCAPACITY_ SENSIBLECAPACITY)
TOTALCAPACITY, COMP KW ANDAPP DEW PT AREVAUD ONLYFOR WET COIL¸ ALLTEMPERATURESIN DEGREES F
22-1728-01-1201
(EN)
33

Advertisement

loading