1.5.8
Set alarm parameters
CH1 - CH8 to set the sensor input type as
'N.O.' : normally open, closed will invoke alarm
'N.C.' : normally closed, open will invoke alarm
'closed' means to short the alarm signal line to the ground
ALARM RESET IN : to set alarm reset input type as 'N.O.' or 'N.C.'
BUZZER : turn the buzzer ON/OFF
KEY LOCK : turn the KEY LOCK function ON or OFF, when key lock is turned on
ALARM HOLD TIME : the time period to buzz (if buzzer is on) and send alarm out
EverFocus Electronics Corp.
ALARM SETTING MENU
CH SENSOR
CH SENSOR
1 N.O.
5 N.O.
2 N.O.
6 N.O.
3 N.O.
7 N.O.
4 N.O.
8 N.O.
ALARM RESET IN : N.O.
BUZZER
: ON
KEY LOCK
: OFF
ALARM HOLD TIME: 05 SEC
1. all keys except SET key are locked
2. KEY LOCK stays ON until we turn it OFF by pressing the SET key
signal when an alarm in
10