Split system heat pump 1 1⁄2 thru 5 tons 208/230 volt, 1-phase, 60 hz

Advertisement

Quick Links

Residential & Light Commercial HVAC
Rated in Accordance with ARI Standard
210/240. Certification Applies Only When Used
with Proper Components as Listed with ARI.
Additional rating information can be found
at www.aridirectory.org
Size
Model
Refrigerant
Number
(tons)
CH18ABD1VF
1
R-22
1
2
CH24ACD1VF
2
R-22
CH30ACD1VF
2
1
R-22
2
CH36ACD1VF
3
R-22
CH42ACD1VF
3
R-22
1
2
CH48ACD1VF
4
R-22
CH60ACZ1VF
5
R-410A
Split System Heat Pump
2Max. Fuse
Nominal
Min. Circuit
BTUH
Ampacity
or Breaker
18,000
13.5
24,000
16.0
30,000
18.8
36,000
20.5
42,000
24.8
48,000
27.3
60,000
38.4
208/230 Volt, 1-Phase, 60 Hz
Performance:
Efficiency rating of 13 SEER
Cooling capacities from 1

Refrigerant Circuit:

Factory installed biflow liquid line filter drier
Long life copper tubes, aluminum fins
State-of-the-art compressors
Large, wrap-around coil surface
Quality Built:
Galvanized steel exterior cabinet with
1,000-hour salt spray, powder-coated finish
Powder-coated fan guard
Full louvered panel to protect coil
Formed base with 2
Limited 5-year warranty on parts
Low pressure port
Integrated solid state control with adjustable
time-temp demand defrost
Easy To Install:
Factory-charged
Only three screws to access electrical controls
Easy access to service valves
Operating Dimensions
H x W x D (inches)
20
32
X 21
X 21
1
1
1
2
2
2
25
32
1
X 29
1
X 29
1
2
2
2
30
32
1
X 29
1
X 29
1
2
2
2
35
32
1
X 29
1
X 29
1
2
2
2
40
32
X 29
X 29
1
1
1
2
2
2
45
32
1
X 29
1
X 29
1
2
2
2
60
39 X 29
1
X 29
1
2
2
1
1
thru 5 Tons
2
1
to 5 tons
2
1
" ground clearance
2
Min. Mounting
Ship / Operating
Pad Size (inches)
Weight (lbs)
24 x 24
132 / 127
32 x 32
195 / 186
32 x 32
195 / 186
32 x 32
197 / 188
32 x 32
208 / 201
32 x 32
212 / 203
32 x 32
258 / 249

Advertisement

loading

Summary of Contents for Fedders CH18ABD1VF

  • Page 1: Refrigerant Circuit

    210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org Size Model Nominal Refrigerant Number BTUH (tons) CH18ABD1VF ⁄ R-22 18,000 CH24ACD1VF R-22 24,000 CH30ACD1VF ⁄ R-22 30,000 CH36ACD1VF...
  • Page 2: Product Specifications

    Product Specifications MODEL SIZE PERFORMANCE DATA NOMINAL CAPACITY (BTUH) FAN DATA FAN MOTOR TYPE DIAMETER BLADE OUTDOOR COIL TYPE COIL FACE AREA (ft O.D. FPI / ROWS ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V) MINIMUM CIRCUIT AMPACITY - MCA (amps) MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP (amps) COMPRESSOR RLA (Rated Load Amps) COMPRESSOR LRA (Locked Rotor Amps)
  • Page 3 HSPF – Heating Seasonal Performance Factor EER – Energy Efficiency Ratio NOTES: 1. Tested combination per ARI 210/240 standard. Fedders air handlers contain the TDR as standard equipment. 2. Supplemental electric heat is not included. 3. Ratings are based on: Cooling Standard: 80ºF db 67ºF wb indoor entering air temperature and 95ºF db air entering outdoor unit.
  • Page 4: Cooling Performance Data

    (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.) Note: See unit installation instructions for proper installation. RATINGS AT STANDARD CONDITIONS OUTDOOR UNIT HANDLER BTUH MODEL SEER* CH18ABD1VF AFPB24A1 18,000 CH24ACD1VF AFPB24B1 24,000 CH30ACD1VF AFPB36A1 28,000...
  • Page 5 Split System Heat Pump Specifications subject to change without notice.
  • Page 6: Model Number

    All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc. Specifications subject to change without notice.