Summary of Contents for Giant GP6132

  • Page 1: Table Of Contents

    Triplex Ceramic Model Plunger Pump Operating Instructions/ Repair and Service GP6132 Manual Contents: Installation Instructions: page 2 Pump Specs: page 3 Exploded View: page 4 Parts List / Kits: page 5 Torque Specifications: page 5 Repair Instructions: page 6 Troubleshooting Chart: page 7 Recommended Spare Parts: page 7...
  • Page 2: Installation Instructions

    50 hours of operation, then at regular intervals of 500 hours or less depending on 4. Run the pump dry approximately 10 seconds operating conditions. to drain the water before exposure to freezing temperatures. NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600...
  • Page 3: Pump Specs

    Specifications Model GP6132 U.S....... Metric Volume ..............23.5 GPM ..... 88.9 LPM Discharge Pressure ..........3045 PSI ....... 210 BAR Speed ......................800 RPM Inlet Pressure ............-4.35 to 145 PSI -0.3 to 10 BAR ....Plunger Diameter ..........1.26” ......32mm Plunger Stroke .............
  • Page 4: Exploded View

    EXPLODED VIEW - GP6132...
  • Page 5: Parts List / Kits

    GP6132 SPARE PARTS LIST ITEM PART DESCRIPTION QTY. ITEM PART DESCRIPTION QTY. 13200 Crankcase 13219 Plunger Connection 13000 Oil Filler Plug Assy 07125 Centering Sleeve 13201 Crankcase Cover 13022 Plunger Pipe 13202 O-Ring for 4 05168 Tensioning Screw 06894 Oil Dipstick 07755 Copper Ring 01009...
  • Page 6: Repair Instructions

    REPAIR INSTRUCTION - GP6132 To Check Valves 1. Loosen plugs (56) and take out complete valve assemblies (51) with a slide hammer. Use a bent piece of wire to remove the o-rings (52). 2. To dismantle the valves, carefully tap the valve plate (51B) with a bolt until the valve seat (51A) is pushed out of the spacer pipe (51D).
  • Page 7: Troubleshooting Chart

    Replace plungers Inlet pressure too high Reduce inlet pressure High Crankcase Wrong Grade of Oil Giant oil is recommended Temperature Improper amount of oil in crankcase Adjust oil level to proper amount Preventative Maintenance Check List & Recommended Spare Parts List...
  • Page 8 A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.