Installation & Operating Instructions Air Conditioning units Manufactured GOETTL AIR CONDITIONING, INC. P.O. Box 52029, Phoenlx, Arlzona 85072-2029...
Page 3
iNSTAELATION 'AND OPERATING INSTRUCTION? MANUA SC MODELS COOLING ONLY - 1 1/2 - S 1/2 TONS Please take a few minutes to read ourinstructionsbefore you installand use yourairconditioner. This will help you obtain the full value from your air conditioner. It will also help you avoid any needless service costs that result from causes we cannot control and cannot cover in our guarantee.
Page 4
when installed inan unconditionedarea. Where It is very important that the ducts for a self- contained system be properly sized, installed, the supply duct is exposed to the outdoor sealed, and insulated for the best performance temperatures, vapor barrier material should be used.
Page 5
Page 9 shows a typical wiring diagram for the at the "L" terminals of contractor, through various units. However, each unit will have its knockout in side of unit. These connections appropriate widng diagram attached to the must be tight and electrically secure. A fused access panel of the wiring control section.
Page 6
ROOF" MOUNTED UNIT WALLS TYPICAL ROOF MOUNTED INSTALLATION with rubber, cork or spring mounts. These This system is a completely serf-contained mounts are to help eliminate vibration and cooling unitwith all components in one cabinet. noise. Ground installationis basicallythe same It is shipped completely charged withthe proper for both self-contained units and split-system amount of refrigerant.
_'_ __ls_extm_ly important thata condensate "P, i_ _condensate trap will prevent the hot and humid -_ tW be installedi in the drain_line below the outside air from being drawn into the _ndi- bottom of the unit, as shown in the sketch tioned space through the drain line, thus below.
Page 8
mometer be placed in the return air and one PREUMINARY START-UP placed in the a_rsupply. After all insulating If power to unit has been disconnected for ofductwork and adjustments of air registers any extended period of time, restore power are complete, a temperature difference of twelve (12) hours prior to start-up proce- 15°...
Resistance are needed, as a differentthermostator sub heatersare available as an op- base may be required. tional field-installed accessory for air condi- tioners. Consult factory if resistance heaters 1. Be sure the filter is clean. Inspect every 30 Your new air conditioner compressor days of operation;...
HOWTO GET THE MAXIMUM PLEASURE _ ture is about the same but there is discomfort. FROM YOUR AIR CONDmONER This is because the humidity is high. Indoors, the air should be beth cool and rela- In order that you may fully enjoy the comfort tively dry for comfort.
Page 12
CT3"- GOETTL AIR CONDITIONING, INC. P.O. Box 52029 • Phoenix, Arizona 85072-2029 613360 Rev. 9/96 2.5M...